Your browser doesn't support javascript.
loading
Experimental periprosthetic fractures with collarless polished tapered cemented stems.
Yagura, Takuma; Oe, Kenichi; Kobayasi, Fumito; Sogawa, Shohei; Nakamura, Tomohisa; Iida, Hirokazu; Saito, Takanori.
Afiliação
  • Yagura T; Department of Orthopaedic Surgery, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan.
  • Oe K; Department of Orthopaedic Surgery, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan. oeken@hirakata.kmu.ac.jp.
  • Kobayasi F; Department of Orthopaedic Surgery, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan.
  • Sogawa S; Department of Orthopaedic Surgery, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan.
  • Nakamura T; Department of Orthopaedic Surgery, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan.
  • Iida H; Department of Orthopaedic Surgery, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan.
  • Saito T; Department of Orthopaedic Surgery, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan.
Int Orthop ; 48(5): 1171-1178, 2024 May.
Article em En | MEDLINE | ID: mdl-38443715
ABSTRACT

PURPOSE:

After cemented total hip arthroplasty, the risk of periprosthetic fracture (PPF) of taper-slip stems is higher than that of composite-beam stems. We aimed to assess the conditions resulting in PPFs of taper-slip stems using a falling weight.

METHODS:

Taper-slip stems were fixed to five types of simulated bone models using bone cement, and the fractures were evaluated by dropping stainless-steel weights from a predetermined height onto the heads. The periprosthetic fracture height in 50% of the bone models (PPFH50) was calculated using the staircase method.

RESULTS:

For the fixation with 0° of flexion, the values for PPFH50 were 61 ± 11, 60 ± 13, above 110, 108 ± 49, and 78 ± 12 cm for the cobalt-chromium-molybdenum alloy, stainless steel alloy (SUS), titanium alloy (Ti), smooth surface, and thick cement mantle models, respectively; for the fixation with 10° of flexion (considering flexure), the PPFH50 values were 77 ± 5, 85 ± 9, 90 ± 2, 89 ± 5, and 81 ± 11 cm, respectively. The fracture rates of the polished-surface stems were 78.6 and 35.7% at the proximal and distal sites, respectively (p < 0.05); the fracture rates of the smooth-surface stems were 14.2 and 100%, respectively (p < 0.05).

CONCLUSION:

The impact tests demonstrated that the conditions that were less likely to cause PPFs were use of Ti, a smooth surface, a thick cement mantle, and probably, use of SUS.