Your browser doesn't support javascript.
loading
Identification of medium- and mechanism-related pitfalls towards improved performance and applicability of electrochemical mercury(II) aptasensors.
Szymczyk, Anna; Popiolek, Martyna; Krzeminski, Jakub; Olszewski, Marcin; Ziólkowski, Robert; Malinowska, Elzbieta.
Afiliação
  • Szymczyk A; Faculty of Chemistry, Warsaw University of Technology, Stanislawa Noakowskiego 3, 00-664, Warsaw, Poland.
  • Popiolek M; Doctoral School, Warsaw University of Technology, Plac Politechniki 1, 00-661, Warsaw, Poland.
  • Krzeminski J; Faculty of Chemistry, Warsaw University of Technology, Stanislawa Noakowskiego 3, 00-664, Warsaw, Poland.
  • Olszewski M; Centre for Advanced Materials and Technologies CEZAMAT, Warsaw University of Technology, Poleczki 19, 02-822, Warsaw, Poland.
  • Ziólkowski R; Faculty of Chemistry, Warsaw University of Technology, Koszykowa 75, 00-664, Warsaw, Poland.
  • Malinowska E; Faculty of Chemistry, Warsaw University of Technology, Stanislawa Noakowskiego 3, 00-664, Warsaw, Poland. robert.ziolkowski@pw.edu.pl.
Mikrochim Acta ; 191(4): 189, 2024 03 08.
Article em En | MEDLINE | ID: mdl-38457045
ABSTRACT
The importance of understanding the mercury (II) ion interactions with thymine-rich DNA sequences is the reason for multiple comparative investigations carried out with the use of optical detection techniques directly in the depth of solution. However, the results of such investigations have limited applicability in the interpretation of the Hg2+ binding phenomenon by DNA sequences in thin, interfacial (electrode/solution), self-organized monolayers immobilized on polarizable surfaces, often used for sensing purposes in electrochemical biosensors. Overlooking the careful optimization of the measurement conditions is the source of discrepancies in the interpretation of the registered electrochemical signal. In this study, the chosen effects accompanying the efficiency of surface related recognition of Hg2+ by polyThymine DNA sequences labelled with methylene blue were investigated by voltammetry, QCM and spectro-electrochemical techniques. As was shown, the composition of the biosensing layer and buffers or the analytical procedures have a significant impact on the registered electrochemical readout which translates into signal stability, the biosensor's working parameters or even the mechanism of detection. After elucidation of the above factors, the complete and ready-to-use biosensor-based analytical solution was proposed offering subpicomolar mercury ion determination with high selectivity (also in aqueous real samples), reusability, and high signal stability even after long-term storage. The developed procedures were successfully used during the miniaturization process with self-prepared (PVD) elastic transducers. The obtained sensor, together with the simplicity of its use, low manufacturing cost, and attractive analytical parameters (i.e., LOD < < Hg2+ WHO limit) can present an interesting alternative for on-site mercury ion detection in environmental samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Mercúrio Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Mercúrio Idioma: En Ano de publicação: 2024 Tipo de documento: Article