Your browser doesn't support javascript.
loading
A Three-Wavelength Optical Sensor for Measuring the Multi-Particle-Size Channel Mass Concentration of Thermal Power Plant Emissions.
Xiao, Xiao; Zhu, Ming; Wang, Qiuyu; Yuan, Xiaodong; Lin, Mengxue.
Afiliação
  • Xiao X; Hubei Key Laboratory of Smart Internet Technology, School of Electronic Information and Communications, Huazhong University of Science and Technology, Wuhan 430074, China.
  • Zhu M; National Engineering Research Center of Fire and Emergency Rescue, Wuhan 430074, China.
  • Wang Q; Hubei Key Laboratory of Smart Internet Technology, School of Electronic Information and Communications, Huazhong University of Science and Technology, Wuhan 430074, China.
  • Yuan X; National Engineering Research Center of Fire and Emergency Rescue, Wuhan 430074, China.
  • Lin M; Hubei Key Laboratory of Smart Internet Technology, School of Electronic Information and Communications, Huazhong University of Science and Technology, Wuhan 430074, China.
Sensors (Basel) ; 24(5)2024 Feb 22.
Article em En | MEDLINE | ID: mdl-38474960
ABSTRACT
Emissions from thermal power plants have always been the central consideration for environmental protection. Existing optical sensors in thermal power plants usually measure the total mass concentration of the particulate matter (PM) by a single-wavelength laser, bearing intrinsic errors owing to the variation in particle size distribution (PSD). However, the total mass concentration alone cannot characterize all the harmful effects of the air pollution caused by the power plant. Therefore, it is necessary to measure the mass concentration and PSD simultaneously, based on which we can obtain multi-particle-size channel mass concentration. To achieve this, we designed an optical sensor based on the three-wavelength technique and tested its performance in a practical environment. Results showed that the prototype cannot only correctly measure the mass concentration of the emitted PM but also determine the mean diameter and standard deviation of the PSDs. Hence, the mass concentrations of PM10, PM2.5, and PM1 are calculated, and the air pollutants emission by a thermal power plant can be estimated comprehensively.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article