Quantum dots-based multiplexed immunosensors for accurate diagnosis of attention deficit hyperactivity disorder in childhood.
J Pharm Biomed Anal
; 243: 116096, 2024 Jun 15.
Article
em En
| MEDLINE
| ID: mdl-38484638
ABSTRACT
Attention-deficit/hyperactivity disorder (ADHD) lacks objective diagnostic markers. In clinical settings, reliance on subjective judgments can often lead to missed or misdiagnoses. Some biomarkers have been reported to be associated with ADHD, but using one biomarker alone is not enough. To address this, we developed a fluorescent immunoassay platform based on quantum dots (QDs) to detect assay capable of detecting and quantifying multiple biomarkers simultaneously. Specifically, we were able to the simultaneously detect brain-derived neurotrophic factor, tumor necrosis factor-alpha, interleukin-6 and ferritin using different emission spectra QDs. The QD-based multiplexed immunoassay displayed a low detection of limit in the range of 0.021-0.068â¯pg/mL, and the assay showed satisfactory reproducibility and precision. We then quantified all four targets from ADHD patient's plasma samples, where it showed remarkable consistency with clinical test for ADHD diagnosis. This methodological comparison supports the diagnosis of ADHD using our assay.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Transtorno do Deficit de Atenção com Hiperatividade
/
Técnicas Biossensoriais
/
Pontos Quânticos
Limite:
Humans
Idioma:
En
Ano de publicação:
2024
Tipo de documento:
Article