Lung transplant airway complications treated with biodegradable airway stents: The Dutch multi-center experience.
Clin Transplant
; 38(3): e15289, 2024 03.
Article
em En
| MEDLINE
| ID: mdl-38486062
ABSTRACT
INTRODUCTION:
Treatment of post lung-transplant airway complications is challenging, and treatment with conventional airway stents is associated with adverse events. More recently, biodegradable airway stents (BDS) have been introduced and may be used to reduce these adverse events. In this study we explore the feasibility of treatment with BDS post lung transplant.METHODS:
All patients treated with BDS in The Netherlands were included in this retrospective multicenter study. Feasibility, life span of the stent, occurrence of adverse events, and evolution of lung function were evaluated.RESULTS:
Twelve patients (six malacia and six stenosis) received a total of 57 BDS, ranging from 1 to 10 BDS per patient. Six patients had been pretreated with conventional airway stents. Median stent life span was 112 days (range 66-202). No adverse events occurred during stent placement. In 5 out of 57 stent placements, a single additional bronchoscopy was necessary because of mucus accumulation (n = 4) or excessive granulation tissue (n = 1). All stent naïve patients became airway stent independent after treatment; all patients pretreated with conventional airway stents were still airway stent dependent at the end of follow up.CONCLUSION:
Treatment with BDS is safe and feasible. Adverse events were mild and easily treatable. All patients with initial treatment with BDS were airway stent independent at the end of follow up with a median treatment of 4 BDS.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Transplante de Pulmão
Limite:
Humans
Idioma:
En
Ano de publicação:
2024
Tipo de documento:
Article