Your browser doesn't support javascript.
loading
Clinical outcomes of patellofemoral arthroplasty: robotic assistance produces superior short and mid-term outcomes.
Katzman, Jonathan L; Buehring, Weston; Haider, Muhammad A; Connolly, Patrick; Schwarzkopf, Ran; Fernandez-Madrid, Ivan.
Afiliação
  • Katzman JL; Department of Orthopedic Surgery, Division of Adult Reconstructive Surgery, NYU Langone Health, NYU Langone Orthopedic Hospital, 301 East 17th Street, New York, NY, 10010, USA. jonathankatzman98@gmail.com.
  • Buehring W; Department of Orthopedic Surgery, Division of Adult Reconstructive Surgery, NYU Langone Health, NYU Langone Orthopedic Hospital, 301 East 17th Street, New York, NY, 10010, USA.
  • Haider MA; Department of Orthopedic Surgery, Division of Adult Reconstructive Surgery, NYU Langone Health, NYU Langone Orthopedic Hospital, 301 East 17th Street, New York, NY, 10010, USA.
  • Connolly P; Department of Orthopedic Surgery, Division of Adult Reconstructive Surgery, NYU Langone Health, NYU Langone Orthopedic Hospital, 301 East 17th Street, New York, NY, 10010, USA.
  • Schwarzkopf R; Department of Orthopedic Surgery, Division of Adult Reconstructive Surgery, NYU Langone Health, NYU Langone Orthopedic Hospital, 301 East 17th Street, New York, NY, 10010, USA.
  • Fernandez-Madrid I; Department of Orthopedic Surgery, Division of Adult Reconstructive Surgery, NYU Langone Health, NYU Langone Orthopedic Hospital, 301 East 17th Street, New York, NY, 10010, USA. Ivan.Fernandez-Madrid@nyulangone.org.
Article em En | MEDLINE | ID: mdl-38492064
ABSTRACT

INTRODUCTION:

Patellofemoral arthroplasty (PFA) has been shown to provide symptomatic improvement for isolated patellofemoral osteoarthritis (PFOA). The efficacy of robotic-assisted PFA and the most suitable PFA implant design, however, remain ongoing matters of debate. This study sought to compare clinical outcomes between patients who underwent robotic-assisted versus conventional PFAs with inlay and onlay prosthetic designs.

METHODS:

A single-center retrospective review found 237 knees (211 patients) which underwent PFA between 2011 and 2021. One hundred eighty-four knees were included in the final analysis after cases were excluded for having indications other than osteoarthritis or having less than one year of follow-up. There were 90 conventional PFAs and 94 robotic-assisted PFAs performed. Inlay components were implanted in 89 knees and onlay components were implanted in 95 knees. Propensity score matching was utilized to address demographic differences between groups.

RESULTS:

Overall, there was a revision-free survivorship rate of 89.7% with an average time to follow-up of 4.6 years (range 1.2 to 11.1). Twenty-nine knees (15.8%) required various non-conversion procedures. The conventional matched cohort exhibited a higher all-cause revision rate, accounting for revision PFAs and conversions to TKA, (18.8 vs. 6.4%, p = 0.014) and a shorter mean time to revision than the robotic-assisted cohort (3.1 vs. 5.8 years, p = 0.026). A Kaplan-Meier survivorship curve showed differences between the conventional and robotics cohorts (p = 0.041). All revisions following robotic-assisted PFA were caused by progression of osteoarthritis, whereas conventional PFAs also required revision due to aseptic loosening and patellar maltracking. The rate of infection resulting in irrigation and debridement was higher for conventional cases (4.3 vs. 0%, p = 0.041). No significant differences in clinical outcomes between the inlay and onlay prosthetic design matched cohorts were identified.

CONCLUSION:

PFA is an effective treatment for addressing advanced patellofemoral arthritis. Robotic-assisted surgery may lead to improved clinical outcomes. LEVEL OF EVIDENCE III.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article