Your browser doesn't support javascript.
loading
Mother-daughter technique for kinked catheter retrieval from radial artery.
Panchal, Hemang B; Patel, Nirav; Bhogal, Sukhdeep; De La Cruz Quezada, Kristal.
Afiliação
  • Panchal HB; Heart Care Cardiovascular Center, Port St. Lucie, Florida, USA.
  • Patel N; Division of Cardiology, Florida Atlantic University, Boca Raton, Florida, USA.
  • Bhogal S; Team Health, Johnson City Medical Center, Johnson City, Tennessee, USA.
  • De La Cruz Quezada K; MedStar Washington Hospital Center, Washington, District of Columbia, USA.
Catheter Cardiovasc Interv ; 103(5): 731-735, 2024 Apr.
Article em En | MEDLINE | ID: mdl-38494678
ABSTRACT
Catheter kinking is not an uncommon scenario during cardiac catheterization via transradial access in patients with tortuous vascular anatomy. Several noninvasive and invasive methods have been described to unkink and retrieve the kinked catheter out of the vessel. We present a novel mother-daughter technique to retrieve a kinked radial artery catheter.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artéria Radial / Mães Limite: Female / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artéria Radial / Mães Limite: Female / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article