Your browser doesn't support javascript.
loading
Preparation of Monolith for Online Extraction and LC-MS Analysis of ß-Estradiol in Serum Via a Simple Multicomponent Reaction.
Cerrato, Andrea; Aita, Sara Elsa; Cavaliere, Chiara; Laganà, Aldo; Montone, Carmela Maria; Piovesana, Susy; Taglioni, Enrico; Capriotti, Anna Laura.
Afiliação
  • Cerrato A; Department of Chemistry, Università di Roma La Sapienza, Piazzale Aldo Moro 5, 00185 Rome, Italy.
  • Aita SE; Department of Chemistry, Università di Roma La Sapienza, Piazzale Aldo Moro 5, 00185 Rome, Italy.
  • Cavaliere C; Department of Chemistry, Università di Roma La Sapienza, Piazzale Aldo Moro 5, 00185 Rome, Italy.
  • Laganà A; Department of Chemistry, Università di Roma La Sapienza, Piazzale Aldo Moro 5, 00185 Rome, Italy.
  • Montone CM; Department of Chemistry, Università di Roma La Sapienza, Piazzale Aldo Moro 5, 00185 Rome, Italy.
  • Piovesana S; Department of Chemistry, Università di Roma La Sapienza, Piazzale Aldo Moro 5, 00185 Rome, Italy.
  • Taglioni E; Department of Chemistry, Università di Roma La Sapienza, Piazzale Aldo Moro 5, 00185 Rome, Italy.
  • Capriotti AL; Department of Chemistry, Università di Roma La Sapienza, Piazzale Aldo Moro 5, 00185 Rome, Italy.
Anal Chem ; 96(11): 4639-4646, 2024 03 19.
Article em En | MEDLINE | ID: mdl-38501258
ABSTRACT
Multicomponent reactions offer efficient and environmentally friendly strategies for preparing monoliths suitable for applications in analytical chemistry. In the described study, a multicomponent reaction was utilized for the one-pot miniaturized preparation of a poly(propargyl amine) polymer inside commercial silica-lined PEEK tubing. The reaction involved only small amounts of reagents and was characterized by atom economy. The resulting monolithic column was incorporated into an autosampler system for the online extraction and cleanup of ß-estradiol from human serum. Sample pretreatment was simplified to a simple dilution with methanol and centrifugation to remove proteins. The resulting platform included LC-MS analysis in multiple reaction monitoring for quantitative analysis of ß-estradiol. The method was validated in serum, demonstrating practical applicability for the monitoring of fertile women. Recoveries were above 94%, and LOD and LOQ values at 0.008 and 0.18 ng mL-1, respectively. The developed platform proved to be competitive with previous methods for solid-phase microextraction of ß-estradiol in serum, with comparable recovery and sensitivity but with the advantage of nearly complete automation. The environmental impact of the process was evaluated as acceptable due to the miniaturization of the monolith synthesis and the automation of extraction. The drawback associated with the LC-MS technique can be reduced by the inclusion of additional analytes in a single investigation. The work demonstrates that multicomponent reactions are versatile, economical, and possibly a green methodology for producing reversed-phase and mixed-mode sorbents, enabling miniaturization of the entire analytical procedure from the preparation of extraction sorbents to analysis.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas em Tandem / Espectrometria de Massa com Cromatografia Líquida Limite: Female / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas em Tandem / Espectrometria de Massa com Cromatografia Líquida Limite: Female / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article