Your browser doesn't support javascript.
loading
Detection of Anatoxins in Human Urine by Liquid Chromatography Triple Quadrupole Mass Spectrometry and ELISA.
Cunningham, Brady R; Lagon, Sarah R; Bragg, William A; Hill, Donna; Hamelin, Elizabeth I.
Afiliação
  • Cunningham BR; Emergency Response Branch, Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341, USA.
  • Lagon SR; Emergency Response Branch, Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341, USA.
  • Bragg WA; Battelle Memorial Institute, Centers for Disease Control and Prevention, 1600 Clifton Road, Atlanta, GA 30333, USA.
  • Hill D; Emergency Response Branch, Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341, USA.
  • Hamelin EI; National Health and Environmental Effects Research, Environmental Protection Agency, 109 T. W. Alexander Drive, Research Triangle Park, NC 27709, USA.
Toxins (Basel) ; 16(3)2024 Mar 01.
Article em En | MEDLINE | ID: mdl-38535795
ABSTRACT
Harmful cyanobacterial blooms are becoming more common and persistent around the world. When in bloom, various cyanobacterial strains can produce anatoxins in high concentrations, which, unlike other cyanobacterial toxins, may be present in clear water. Potential human and animal exposures to anatoxins occur mainly through unintentional ingestion of contaminated algal mats and water. To address this public health threat, we developed and validated an LC-MS/MS method to detect anatoxins in human urine to confirm exposures. Pooled urine was fortified with anatoxin-a and dihydroanatoxin at concentrations from 10.0 to 500 ng/mL to create calibrators and quality control samples. Samples were diluted with isotopically labeled anatoxin and solvent prior to LC-MS/MS analysis. This method can accurately quantitate anatoxin-a with inter- and intraday accuracies ranging from 98.5 to 103% and relative standard deviations < 15%, which is within analytical guidelines for mass spectrometry methods. Additionally, this method qualitatively detects a common degradation product of anatoxin, dihydroanatoxin, above 10 ng/mL. We also evaluated a commercial anatoxin-a ELISA kit for potential diagnostic use; however, numerous false positives were detected from unexposed individual human urine samples. In conclusion, we have developed a method to detect anatoxins precisely and accurately in urine samples, addressing a public health area of concern, which can be applied to future exposure events.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tropanos / Água / Espectrometria de Massas em Tandem / Toxinas de Cianobactérias Limite: Animals / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tropanos / Água / Espectrometria de Massas em Tandem / Toxinas de Cianobactérias Limite: Animals / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article