Your browser doesn't support javascript.
loading
Predictive performance of corneal and lid margin sensitivity for dry eye disease: An investigator-masked, prospective, prognostic accuracy study.
Wang, Michael T M; Meyer, Jay J; Xue, Ally L; Power, Barry; Craig, Jennifer P.
Afiliação
  • Wang MTM; Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, New Zealand.
  • Meyer JJ; Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, New Zealand.
  • Xue AL; Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, New Zealand.
  • Power B; Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, New Zealand; Department of Ophthalmology, Royal Victoria Eye and Ear Hospital, Dublin, Ireland.
  • Craig JP; Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, New Zealand. Electronic address: jp.craig@auckland.ac.nz.
Ocul Surf ; 33: 11-15, 2024 Jul.
Article em En | MEDLINE | ID: mdl-38554989
ABSTRACT

PURPOSE:

To evaluate the prognostic ability of non-contact esthesiometry corneal and lid margin sensitivity measurements in detecting symptoms and signs of dry eye disease, as defined by the global consensus TFOS DEWS II criteria.

METHODS:

A total of 87 community residents (58 females; mean ± SD age, 53 ± 16 years) were recruited in an investigator-masked, prospective, prognostic accuracy study. Dry eye symptomology, tear film parameters, and ocular surface characteristics were evaluated in a single clinical session, and non-contact esthesiometry corneal and lid margin sensitivity measurements performed by an independent masked assessor.

RESULTS:

Overall, 49 (56%) participants fulfilled the TFOS DEWS II criteria for dry eye disease, while 57 (66%) exhibited clinical symptoms, and 67 (77%) had positive signs. The prognostic abilities of corneal and lid margin sensitivity measurements were significantly greater than chance for the detection dry eye signs (both p ≤ 0.03), but not for symptoms or overall disease diagnosis (all p > 0.10). The Youden-optimal prognostic cut-offs for corneal and lid margin sensitivity thresholds were both ≥0.8 mbar for the detection of clinical dry eye signs. Lid margin sensitivity demonstrated marginally higher predictive performance than corneal sensitivity (C-statistic, 0.688 versus 0.658), and was significantly correlated with tear film stability, corneal, conjunctival and lid wiper staining (all p < 0.05).

CONCLUSIONS:

Corneal and lid margin sensitivity demonstrated moderate prognostic utility for detecting clinical dry eye signs. Future research is warranted to investigate the utility of incorporating non-contact esthesiometry in the workup for dry eye disease and neurotrophic keratopathy.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Lágrimas / Síndromes do Olho Seco / Córnea Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Lágrimas / Síndromes do Olho Seco / Córnea Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article