How modular porous metal augments have changed the management of acetabular bone loss at primary or revision total hip arthroplasty.
Bone Joint J
; 106-B(4): 312-318, 2024 Apr 01.
Article
em En
| MEDLINE
| ID: mdl-38555951
ABSTRACT
The advent of modular porous metal augments has ushered in a new form of treatment for acetabular bone loss. The function of an augment can be seen as reducing the size of a defect or reconstituting the anterosuperior/posteroinferior columns and/or allowing supplementary fixation. Depending on the function of the augment, the surgeon can decide on the sequence of introduction of the hemispherical shell, before or after the augment. Augments should always, however, be used with cement to form a unit with the acetabular component. Given their versatility, augments also allow the use of a hemispherical shell in a position that restores the centre of rotation and biomechanics of the hip. Progressive shedding or the appearance of metal debris is a particular finding with augments and, with other radiological signs of failure, should be recognized on serial radiographs. Mid- to long-term outcomes in studies reporting the use of augments with hemispherical shells in revision total hip arthroplasty have shown rates of survival of > 90%. However, a higher risk of failure has been reported when augments have been used for patients with chronic pelvic discontinuity.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Doenças Ósseas Metabólicas
/
Artroplastia de Quadril
/
Prótese de Quadril
Limite:
Humans
Idioma:
En
Ano de publicação:
2024
Tipo de documento:
Article