Your browser doesn't support javascript.
loading
Design of a flow modulation device to facilitate individualized ventilation in a shared ventilator setup.
Stiers, Michiel; Vercauteren, Jan; Schepens, Tom; Mergeay, Matthias; Janssen, Luc; Hoogmartens, Olivier; Neyrinck, Arne; Marinus, Benoît G; Sabbe, Marc.
Afiliação
  • Stiers M; Department of Public Health and Primary Care, Research unit Emergency Medicine, KU Leuven, 3000, Leuven, Belgium. michiel.stiers@kuleuven.be.
  • Vercauteren J; Department of Emergency Medicine, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium. michiel.stiers@kuleuven.be.
  • Schepens T; Department of Mechanical Engineering, Royal Military Academy, Renaissancelaan 30, Brussels, Belgium.
  • Mergeay M; Department of Intensive Care Medicine, Ghent University Hospital, C Heymanslaan 10, Ghent, Belgium.
  • Janssen L; Department of Anesthesiology and Critical Care Medicine, St-Dimpna, J.-B. Stessensstraat 2, 2440, Geel, Belgium.
  • Hoogmartens O; Department of Anesthesiology and Critical Care Medicine, St-Dimpna, J.-B. Stessensstraat 2, 2440, Geel, Belgium.
  • Neyrinck A; Department of Public Health and Primary Care, Research unit Emergency Medicine, KU Leuven, 3000, Leuven, Belgium.
  • Marinus BG; Department of Emergency Medicine, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium.
  • Sabbe M; Department of Cardiovascular Sciences, Research unit Anesthesiology and Algology, KU Leuven, 3000, Leuven, Belgium.
J Clin Monit Comput ; 38(3): 679-690, 2024 Jun.
Article em En | MEDLINE | ID: mdl-38557919
ABSTRACT
This study aims to resolve the unmet need for ventilator surge capacity by developing a prototype device that can alter patient-specific flow in a shared ventilator setup. The device is designed to deliver a predictable tidal volume (VT), requiring minimal additional monitoring and workload. The prototyped device was tested in an in vitro bench setup for its performance against the intended use and design criteria. The ventilation parameters VT and airway pressures, and ventilation profiles pressure, flow and volume were measured for different ventilator and device settings for a healthy and ARDS simulated lung pathology. We obtained VTs with a linear correlation with valve openings from 10 to 100% across set inspiratory pressures (IPs) of 20 to 30 cmH2O. Airway pressure varied with valve opening and lung elastance but did not exceed set IPs. Performance was consistent in both healthy and ARDS-simulated lung conditions. The ventilation profile diverged from traditional pressure-controlled profiles. We present the design a flow modulator to titrate VTs in a shared ventilator setup. Application of the flow modulator resulted in a characteristic flow profile that differs from pressure- or volume controlled ventilation. The development of the flow modulator enables further validation of the Individualized Shared Ventilation (ISV) technology with individualization of delivered VTs and the development of a clinical protocol facilitating its clinical use during a ventilator surge capacity problem.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Respiração Artificial / Síndrome do Desconforto Respiratório / Ventiladores Mecânicos / Volume de Ventilação Pulmonar / Desenho de Equipamento / Pulmão Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Respiração Artificial / Síndrome do Desconforto Respiratório / Ventiladores Mecânicos / Volume de Ventilação Pulmonar / Desenho de Equipamento / Pulmão Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article