Your browser doesn't support javascript.
loading
Functional electrostimulation therapy for vastus medialis decreases the varus thrust during gait.
Shimada, Noboru; Shimada, Masashi; Toriyama, Minoru; Ishikawa, Masakazu; Hirata, Kazuhiko; Kono, Yoshifumi; Ushio, Kai; Mikami, Yukio; Adachi, Nobuo.
Afiliação
  • Shimada N; Division of Rehabilitation, Department of Clinical Support, Hiroshima University Hospital: 1-2-3 Kasumi, Minami-ku, Hiroshima-shi, Hiroshima 734-8553, Japan.
  • Shimada M; Division of Rehabilitation, Department of Clinical Support, Hiroshima University Hospital: 1-2-3 Kasumi, Minami-ku, Hiroshima-shi, Hiroshima 734-8553, Japan.
  • Toriyama M; Division of Sports Medical Center, Department of Clinical Support, Hiroshima University Hospital, Japan.
  • Ishikawa M; Department of Orthopedic Surgery, Faculty of Medicine, Kagawa University, Japan.
  • Hirata K; Division of Rehabilitation, Department of Clinical Support, Hiroshima University Hospital: 1-2-3 Kasumi, Minami-ku, Hiroshima-shi, Hiroshima 734-8553, Japan.
  • Kono Y; Division of Rehabilitation, Department of Clinical Support, Hiroshima University Hospital: 1-2-3 Kasumi, Minami-ku, Hiroshima-shi, Hiroshima 734-8553, Japan.
  • Ushio K; Department of Rehabilitation, Hiroshima University Hospital, Japan.
  • Mikami Y; Department of Rehabilitation, Hiroshima University Hospital, Japan.
  • Adachi N; Department of Orthopaedic Surgery, Graduate School of Biomedical and Health Sciences, Hiroshima University, Japan.
J Phys Ther Sci ; 36(4): 190-194, 2024 Apr.
Article em En | MEDLINE | ID: mdl-38562536
ABSTRACT
[Purpose] This study aimed to investigate whether modification of vastus medialis activity can delay the varus thrust. [Participants and Methods] Ten participants (Kellgren-Laurence grades I n=2, II n=6, and III n=2) diagnosed with knee osteoarthritis were enrolled. The intervention involved free walking on a 10-m walkway at any speed after donning a functional electrical stimulation set to contract the vastus medialis before heel contact. Using a Vicon Nexus ground reaction force meter and a wireless electromyograph DELSYS, varus thrust, maximal knee extension angle, maximal knee adduction moment, and vastus medialis onset time were assessed both before and after intervention. [Results] A significant difference in varus thrust was detected from before to after the intervention (2.7 ± 1.1° vs. 2.2 ± 1.3°). Both the vastus medialis activation time (-0.06 ± 0.09 vs. -0.21 ± 0.1) and the knee-joint extension angle (8.7 ± 5.1° vs. 5.5 ± 5.9°) decreased following intervention, whereas the knee adduction moment significantly increased (0.50 ± 0.20° vs 0.56 ± 0.18°). [Conclusion] Wearing the functional electrical stimulation set caused the vastus medialis to act earlier in response to heel strike, thereby improving the knee-joint extension angle and suppressing varus thrust.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article