Your browser doesn't support javascript.
loading
Development of a protocol for standardized use of a water-soluble contrast agent with polyethylene glycol in post-mortem CT angiography.
Bruch, G M; Grabherr, S; Bruguier, C; Fischer, F T; Soto, R; Magnin, V; Genet, P.
Afiliação
  • Bruch GM; Institut Für Rechtsmedizin, Ludwig-Maximillians-Universität München, Nussbaumstr. 26, D - 80336, Munich, Deutschland. gina.bruch@med.uni-muenchen.de.
  • Grabherr S; Centre Universitaire Romand de Médecine Légale, Centre Hospitalier Universitaire Vaudois, Chemin de La Vulliette 4, CH - 1000, Lausanne 25, Schweiz. gina.bruch@med.uni-muenchen.de.
  • Bruguier C; Université de Genève, Rue du Général-Dufour 24, CH - 1211, Geneva 4, Schweiz. gina.bruch@med.uni-muenchen.de.
  • Fischer FT; Centre Universitaire Romand de Médecine Légale, Centre Hospitalier Universitaire Vaudois, Chemin de La Vulliette 4, CH - 1000, Lausanne 25, Schweiz.
  • Soto R; Centre Universitaire Romand de Médecine Légale, Hôpitaux Universitaires de Genève, Rue Michel-Servet 1, CH - 1211, Geneva 4, Schweiz.
  • Magnin V; Centre Universitaire Romand de Médecine Légale, Centre Hospitalier Universitaire Vaudois, Chemin de La Vulliette 4, CH - 1000, Lausanne 25, Schweiz.
  • Genet P; Institut Für Rechtsmedizin, Ludwig-Maximillians-Universität München, Nussbaumstr. 26, D - 80336, Munich, Deutschland.
Int J Legal Med ; 138(4): 1437-1446, 2024 Jul.
Article em En | MEDLINE | ID: mdl-38568229
ABSTRACT
Computed tomography angiography (PMCTA) is increasingly used in postmortem cases. Standardized validated protocols permit to compare different PMCTA images and make it more easily to defend a case in court. In addition to the well-known technique by Grabherr et al. (2011) which is using paraffin oil as a carrier substance, water-soluble polyethylene glycol 200 (PEG200) can be used in combination with the contrast agent Accupaque® 300. As to date, there exists no standardized protocol for the use of this contrast agent mixture, the aim of this study was to develop a protocol using it. Between 2012 and 2022, 23 PMCTA with PEG200 and Accupaque®300 were performed at the University Centre of Legal Medicine Lausanne (Switzerland) and the Institute of Forensic Medicine Munich (Germany). The images obtained were evaluated regarding the opacification of the vessels and possible artefacts. The best image quality was obtained with a mixing ratio of 115 (Accupaque®300PEG200) and a perfusion volume of 1000 ml in the arterial, 1400 ml in the venous and 350 ml in the dynamic phase. The infusion rates described by Grabherr et al. were confirmed for the three phases. Overall, the opacification of the vessels was diagnostically sufficient. In 13 cases no opacification of the right coronary artery was observed due to a stratification artefact. By using the PMCTA protocol with PEG200 as a carrier, a good overall image quality can be achieved. This protocol offers the possibility to standardize PMCTA with PEG200.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polietilenoglicóis / Meios de Contraste / Angiografia por Tomografia Computadorizada Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polietilenoglicóis / Meios de Contraste / Angiografia por Tomografia Computadorizada Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article