Ultra-sensitive fluorescent biosensor for multiple bacteria detection based on CDs/QDs@ZIF-8 and microfluidic fluidized bed.
Huang, Fengchun; Sun, Chongsi; Dong, Jinying; Wu, Xiaoya; Du, Yuguang; Hu, Qiushi; Zhou, Lei.
Afiliação
  • Huang F; National Key Laboratory of Biochemical Engineering, PLA Key Laboratory of Biopharmaceutical Production & Formulation Engineering, Institute of Process Engineering, Chinese Academy of Sciences, Beijing, 100190, People's Republic of China.
  • Sun C; Innovation Academy for Green Manufacture Institute, Chinese Academy of Sciences, Beijing, 100190, People's Republic of China.
  • Dong J; Institute of Agro-Product Quality and Safety, of Quality Standard & Testing Technology for Agro-Products, Key Laboratory, Chinese Academy of Agricultural Sciences, Beijing, 100081, China.
  • Wu X; National Key Laboratory of Biochemical Engineering, PLA Key Laboratory of Biopharmaceutical Production & Formulation Engineering, Institute of Process Engineering, Chinese Academy of Sciences, Beijing, 100190, People's Republic of China.
  • Du Y; Innovation Academy for Green Manufacture Institute, Chinese Academy of Sciences, Beijing, 100190, People's Republic of China.
  • Hu Q; National Key Laboratory of Biochemical Engineering, PLA Key Laboratory of Biopharmaceutical Production & Formulation Engineering, Institute of Process Engineering, Chinese Academy of Sciences, Beijing, 100190, People's Republic of China.
  • Zhou L; University of Chinese Academy of Sciences, Beijing, 100049, People's Republic of China.
Mikrochim Acta ; 191(5): 237, 2024 04 03.
Article em En | MEDLINE | ID: mdl-38570419
ABSTRACT
An ultra-sensitive fluorescent biosensor based on CDs/QDs@ZIF-8 and microfluidic fluidized bed was developed for rapid and ultra-sensitive detection of multiple target bacteria. The zeolitic imidazolate frameworks (ZIF-8) act as the carrier to encapsulate three kinds of fluorescence signal molecules from the CDs/QDs@ZIF-8 signal amplification system. Besides, three kinds of target pathogenic bacteria were automatically, continuously, and circularly captured by the magnetic nanoparticles (MNPs) in the microfluidic fluidized bed. The neutral Na2EDTA solution was the first time reported to not only dissolve the ZIF-8 frameworks from the MNPs-bacteria-CDs/QDs@ZIF-8 sandwich complexes, but also release the CDs/QDs from sandwich complexes with no loss of fluorescence signal. Due to the advantages of signal amplification and automated sample pretreatment, the proposed fluorescent biosensor can simultaneously detect Escherichia coli O157H7, Salmonella paratyphi A, and Salmonella paratyphi B as low as 101 CFU/mL within 1.5 h, respectively. The mean recovery in spiked milk samples can reach 99.18%, verifying the applicability of this biosensor in detecting multiple bacteria in real samples.