Detection and Evaluation for High-Quality Cardiopulmonary Resuscitation Based on a Three-Dimensional Motion Capture System: A Feasibility Study.
Tang, Xingyi; Wang, Yan; Ma, Haoming; Wang, Aoqi; Zhou, You; Li, Sijia; Pei, Runyuan; Cui, Hongzhen; Peng, Yunfeng; Piao, Meihua.
Afiliação
  • Tang X; School of Nursing, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100144, China.
  • Wang Y; School of Nursing, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100144, China.
  • Ma H; School of Nursing, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100144, China.
  • Wang A; School of Nursing, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100144, China.
  • Zhou Y; School of Nursing, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100144, China.
  • Li S; School of Nursing, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100144, China.
  • Pei R; School of Nursing, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100144, China.
  • Cui H; School of Computer and Communication Engineering, University of Science and Technology Beijing, Beijing 100083, China.
  • Peng Y; School of Computer and Communication Engineering, University of Science and Technology Beijing, Beijing 100083, China.
  • Piao M; School of Nursing, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100144, China.
Sensors (Basel) ; 24(7)2024 Mar 27.
Article em En | MEDLINE | ID: mdl-38610365
ABSTRACT
High-quality cardiopulmonary resuscitation (CPR) and training are important for successful revival during out-of-hospital cardiac arrest (OHCA). However, existing training faces challenges in quantifying each aspect. This study aimed to explore the possibility of using a three-dimensional motion capture system to accurately and effectively assess CPR operations, particularly about the non-quantified arm postures, and analyze the relationship among them to guide students to improve their performance. We used a motion capture system (Mars series, Nokov, China) to collect compression data about five cycles, recording dynamic data of each marker point in three-dimensional space following time and calculating depth and arm angles. Most unstably deviated to some extent from the standard, especially for the untrained students. Five data sets for each parameter per individual all revealed statistically significant differences (p < 0.05). The correlation between Angle 1' and Angle 2' for trained (rs = 0.203, p < 0.05) and untrained students (rs = -0.581, p < 0.01) showed a difference. Their performance still needed improvement. When conducting assessments, we should focus on not only the overall performance but also each compression. This study provides a new perspective for quantifying compression parameters, and future efforts should continue to incorporate new parameters and analyze the relationship among them.