Your browser doesn't support javascript.
loading
Innovative Metaheuristic Optimization Approach with a Bi-Triad for Rehabilitation Exoskeletons.
Sosa Méndez, Deira; García Cena, Cecilia E; Bedolla-Martínez, David; Martín González, Antonio.
Afiliação
  • Sosa Méndez D; Escuela Técnica Superior de Ingeniería y Diseño Industrial, Center for Automation and Robotics, UPM-CSIC, Universidad Politécnica de Madrid, Ronda de Valencia, 3, 28012 Madrid, Spain.
  • García Cena CE; Escuela Técnica Superior de Ingeniería y Diseño Industrial, Center for Automation and Robotics, UPM-CSIC, Universidad Politécnica de Madrid, Ronda de Valencia, 3, 28012 Madrid, Spain.
  • Bedolla-Martínez D; Electrical Engineering, École de Technologie Supérieure, 1100 Notre-Dame St. W, Montreal, QC H3C 1K3, Canada.
  • Martín González A; Unidad de Tecnologías Avanzadas en Diseño e Impresión 3D, Hospital Universitario 12 de Octubre, Av. de Córdoba, s/n, 28041 Madrid, Spain.
Sensors (Basel) ; 24(7)2024 Mar 30.
Article em En | MEDLINE | ID: mdl-38610443
ABSTRACT
The present work proposes a comprehensive metaheuristic methodology for the development of a medical robot for the upper limb rehabilitation, which includes the topological optimization of the device, kinematic models (5 DOF), human-robot interface, control and experimental tests. This methodology applies two cutting-edge triads (1) the three points of view in engineering design (client, designer and community) and (2) the triad formed by three pillars of Industry 4.0 (autonomous machines and systems, additive manufacturing and simulation of virtual environments). By applying the proposed procedure, a robotic mechanism was obtained with a reduction of more than 40% of its initial weight and a human-robot interface with three modes of operation and a biomechanically viable kinematic model for humans. The digital twin instance and its evaluation through therapeutic routines with and without disturbances was assessed; the average RMSEs obtained were 0.08 rad and 0.11 rad, respectively. The proposed methodology is applicable to any medical robot, providing a versatile and effective solution for optimizing the design and development of healthcare devices. It adopts an innovative and scalable approach to enhance their processes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Robótica / Exoesqueleto Energizado Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Robótica / Exoesqueleto Energizado Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article