Real-time imaging of ipsilateral parathyroid glands by retrograde injection of methylene blue into the superior thyroid artery: a new intraoperative parathyroid protection method.
Guo, Hanjie; Zhang, Yuxing; Ren, Saiyu; Yang, Xiaodong; Tian, Lei; Huang, Yun; Zhang, Chaojun; Zhang, Xiliang.
Afiliação
  • Guo H; School of Medicine, South China University of Technology, 382 Waihuan Rd E, Panyu, Guangzhou, 510006, People's Republic of China.
  • Zhang Y; Department of General Surgery, The Sixth Medical Center of PLA General Hospital, 6 Fucheng Road, Haidian, Beijing, 100048, People's Republic of China.
  • Ren S; Department of General Surgery, The First Medical Center of PLA General Hospital, 28 Fuxing Road, Haidian, Beijing, 100853, People's Republic of China.
  • Yang X; School of Medicine, South China University of Technology, 382 Waihuan Rd E, Panyu, Guangzhou, 510006, People's Republic of China.
  • Tian L; Department of General Surgery, The Sixth Medical Center of PLA General Hospital, 6 Fucheng Road, Haidian, Beijing, 100048, People's Republic of China.
  • Huang Y; Department of General Surgery, The First Medical Center of PLA General Hospital, 28 Fuxing Road, Haidian, Beijing, 100853, People's Republic of China.
  • Zhang C; Department of General Surgery, The First Medical Center of PLA General Hospital, 28 Fuxing Road, Haidian, Beijing, 100853, People's Republic of China.
  • Zhang X; Department of General Surgery, The First Medical Center of PLA General Hospital, 28 Fuxing Road, Haidian, Beijing, 100853, People's Republic of China.
BMC Surg ; 24(1): 108, 2024 Apr 13.
Article em En | MEDLINE | ID: mdl-38615003
ABSTRACT

BACKGROUND:

Postoperative hypoparathyroidism caused by parathyroid injury is a problem faced by thyroid surgeons. The current technologies for parathyroid imaging all have some defects.

METHODS:

Patients with differentiated thyroid carcinoma (DTC) who underwent unilateral thyroidectomy plus ipsilateral central lymph node dissection were recruited. We dissected the main trunk of the superior thyroid artery entering the thyroid gland and placed the venous indwelling tube into the artery. The sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) were calculated.

RESULTS:

A total of 132 patients enrolled in this single-arm clinical trial, 105 of them completed retrograde catheterization via the superior artery. The sensitivity was 69.23 and 83.33% respectively. The specificity was 72.91 and 64.89%. The accuracy was 72.91 and 64.89%. The PPV was 85.71 and 81.08%. The NPV was 22.58 and 45.45%. There were no patients with allergic reactions to the methylene blue, or methylene blue toxicity.

CONCLUSIONS:

Retrograde injection of methylene blue via the superior thyroid artery is an effective and safe method to visualize parathyroid glands. This method can accurately locate the target organ by ultraselecting the blood vessel and injecting the contrast agent while avoiding background contamination and reducing the amount of contrast agent. TRIAL REGISTRATION Clinical trial registration numbers and date of registration ChiCTR2300077263、02/11/2023.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glândulas Paratireoides / Glândula Tireoide Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glândulas Paratireoides / Glândula Tireoide Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article