CNN application for automated determination of the patient's size to obtain the size-specific dose estimated in CT.
Hernández-Dávila, Erik R; Torres-García, Eugenio; Aranda-Lara, Liliana; Roldan-Valadez, Ernesto; Isaac-Olivé, Keila; Flores-Reyes, Mario.
Afiliação
  • Hernández-Dávila ER; Facultad de Ciencias de Ciencias de la Conducta, Universidad Autónoma del Estado de México, Toluca, México, Mexico.
  • Torres-García E; Facultad de Medicina, Universidad Autónoma del Estado de México, Toluca, México, Mexico.
  • Aranda-Lara L; Facultad de Medicina, Universidad Autónoma del Estado de México, Toluca, México, Mexico.
  • Roldan-Valadez E; Division of Research, Instituto Nacional de Rehabilitación "Luis Guillermo Ibarra Ibarra", 14389, Mexico City, Mexico.
  • Isaac-Olivé K; Facultad de Medicina, Universidad Autónoma del Estado de México, Toluca, México, Mexico.
  • Flores-Reyes M; Facultad de Medicina, Universidad Autónoma del Estado de México, Toluca, México, Mexico.
Biomed Phys Eng Express ; 10(3)2024 Apr 26.
Article em En | MEDLINE | ID: mdl-38631317
ABSTRACT
Introduction. The currently available dosimetry techniques in computed tomography can be inaccurate which overestimate the absorbed dose. Therefore, we aimed to provide an automated and fast methodology to more accurately calculate the SSDE usingDwobtained by using CNN from thorax and abdominal CT study images.Methods. The SSDE was determined from the 200 records files. For that purpose, patients' size was measured in two ways (a) by developing an algorithm following the AAPM Report No. 204 methodology; and (b) using a CNN according to AAPM Report No. 220.Results. The patient's size measured by the in-house software in the region of thorax and abdomen was 27.63 ± 3.23 cm and 28.66 ± 3.37 cm, while CNN was 18.90 ± 2.6 cm and 21.77 ± 2.45 cm. The SSDE in thorax according to 204 and 220 reports were 17.26 ± 2.81 mGy and 23.70 ± 2.96 mGy for women and 17.08 ± 2.09 mGy and 23.47 ± 2.34 mGy for men. In abdomen was 18.54 ± 2.25 mGy and 23.40 ± 1.88 mGy in women and 18.37 ± 2.31 mGy and 23.84 ± 2.36 mGy in men.Conclusions. Implementing CNN-based automated methodologies can contribute to fast and accurate dose calculations, thereby improving patient-specific radiation safety in clinical practice.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doses de Radiação / Algoritmos / Tomografia Computadorizada por Raios X Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doses de Radiação / Algoritmos / Tomografia Computadorizada por Raios X Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article