Your browser doesn't support javascript.
loading
Biomechanical analysis and comparison between 'Zeta' miniplate design and conventional miniplate system for fixation of fracture segments in transition zone of parasymphysis body region of mandible - an in vitro study.
Kumar, Manish; Aurora, Jitender Kumar; Dubey, K N; Tandon, Parul; Sharma, Preeti.
Afiliação
  • Kumar M; Department of Oral and Maxillofacial Surgery, Saraswati Dental College & Hospital, Tiwariganj, Lucknow, UP, India. Electronic address: kashyap294@gmail.com.
  • Aurora JK; Department of Oral and Maxillofacial Surgery, Saraswati Dental College & Hospital, Tiwariganj, Lucknow, UP, India. Electronic address: jkauroramaxfac@gmail.com.
  • Dubey KN; Department of Oral and Maxillofacial Surgery, Saraswati Dental College & Hospital, Tiwariganj, Lucknow, UP, India. Electronic address: kndubey@gmail.com.
  • Tandon P; Department of Oral and Maxillofacial Surgery, Saraswati Dental College & Hospital, Tiwariganj, Lucknow, UP, India. Electronic address: parul.tandon12@gmail.com.
  • Sharma P; Kanachur Institute of Medical Sciences, Mangalore, Karnataka, India. Electronic address: sharma.sgr24@gmail.com.
Br J Oral Maxillofac Surg ; 62(5): 441-447, 2024 Jun.
Article em En | MEDLINE | ID: mdl-38637215
ABSTRACT
The parasymphysis area of the mandible is highly dynamic because it is subjected to both occlusal and muscular forces. As a result, the fractures in this transition zone have a special pattern, posing a challenge for surgeons whether to use one miniplate versus two miniplates, as per Champy's recommendations. The commonest complication resulting to treat this area is mental nerve paraesthesia due to the dissection and stretching of the nerve. Hence, an in vitro research study of a newly designed 'Zeta' miniplate is performed, to evaluate the biomechanical behaviour using finite element (FE) analysis and biomechanical analysis along with a comparison study with the conventional miniplate configurations. The results showed that the Zeta miniplate produces the lowest stresses 17.511 MPa and the least total structural deformation of 0.0011 mm after applying the maximum occlusal bite force. On application of torsional load, total structural deformation was 0.0004 mm and von Mises (VM) stress value was 0.24 MPa which was lowest when compared with the two miniplate system. Hence, the newly developed Zeta miniplate is superior in terms of stability. Another benefit of its design is that it helps in preventing mental nerve paraesthesia and tooth root damage while fixing and stabilising the fractured bony segments.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estresse Mecânico / Força de Mordida / Placas Ósseas / Análise de Elementos Finitos / Fixação Interna de Fraturas / Mandíbula / Fraturas Mandibulares Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estresse Mecânico / Força de Mordida / Placas Ósseas / Análise de Elementos Finitos / Fixação Interna de Fraturas / Mandíbula / Fraturas Mandibulares Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article