Your browser doesn't support javascript.
loading
Experimental evaluation of accuracy and efficiency of two control strategies for a novel foot commanded robotic laparoscope holders with surgeons.
Yang, Yan-Jun; Vadivelu, Arvind Kumar N; Hepworth, Jessica; Zeng, Yongpeng; Pilgrim, Charles H C; Kulic, Dana; Abdi, Elahe.
Afiliação
  • Yang YJ; Department of Mechanical and Aerospace Engineering, Monash University, Clayton, VIC, 3800, Australia. yanjun.yang@monash.edu.
  • Vadivelu AKN; The Department of Mechanical Engineering, The University of Melbourne, Parkville, VIC, 3010, Australia.
  • Hepworth J; Department of Mechanical and Aerospace Engineering, Monash University, Clayton, VIC, 3800, Australia.
  • Zeng Y; Department of Mechanical and Aerospace Engineering, Monash University, Clayton, VIC, 3800, Australia.
  • Pilgrim CHC; Suite 29, Cabrini Medical Centre, Malvern, 3144, VIC, Australia.
  • Kulic D; The Alfred Hospital, Malvern, VIC, 3144, Australia.
  • Abdi E; Faculty of Medicine, Monash University, Clayton, VIC, 3800, Australia.
Sci Rep ; 14(1): 9264, 2024 04 23.
Article em En | MEDLINE | ID: mdl-38649705
ABSTRACT
The implementation of a laparoscope-holding robot in minimally invasive surgery enhances the efficiency and safety of the operation. However, the extra robot control task can increase the cognitive load on surgeons. A suitable interface may simplify the control task and reduce the surgeon load. Foot interfaces are commonly used for commanding laparoscope-holding robots, with two control strategies available decoupled control permits only one Cartesian axis actuation, known as decoupled commands; hybrid control allows for both decoupled commands and multiple axes actuation, known as coupled commands. This paper aims to determine the optimal control strategy for foot interfaces by investigating two common assumptions in the literature (1) Decoupled control is believed to result in better predictability of the final laparoscopic view orientation, and (2) Hybrid control has the efficiency advantage in laparoscope control. Our user study with 11 experienced and trainee surgeons shows that decoupled control has better predictability than hybrid control, while both approaches are equally efficient. In addition, using two surgery-like tasks in a simulator, users' choice of decoupled and coupled commands is analysed based on their level of surgical experience and the nature of the movement. Results show that trainee surgeons tend to issue more commands than the more experienced participants. Single decoupled commands were frequently used in small view adjustments, while a mixture of coupled and decoupled commands was preferred in larger view adjustments. A guideline for foot interface control strategy selection is provided.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Laparoscopia / Procedimentos Cirúrgicos Robóticos / Cirurgiões Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Laparoscopia / Procedimentos Cirúrgicos Robóticos / Cirurgiões Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article