Your browser doesn't support javascript.
loading
Identification of Individual Target Molecules Using Antibody-Decorated DeepTipTM Atomic-Force Microscopy Probes.
Corregidor-Ortiz, Daniel; Daza, Rafael; Colchero, Luis; Tabraue-Rubio, Raquel; Atienza, José Miguel; Elices, Manuel; Guinea, Gustavo V; Pérez-Rigueiro, José.
Afiliação
  • Corregidor-Ortiz D; Departamento de Ciencia de Materiales, ETSI Caminos, Canales y Puertos, Universidad Politécnica de Madrid, 28040 Madrid, Spain.
  • Daza R; Center for Biomedical Technology (CTB), Universidad Politécnica de Madrid, Pozuelo de Alarcón, 28223 Madrid, Spain.
  • Colchero L; Departamento de Ciencia de Materiales, ETSI Caminos, Canales y Puertos, Universidad Politécnica de Madrid, 28040 Madrid, Spain.
  • Tabraue-Rubio R; Center for Biomedical Technology (CTB), Universidad Politécnica de Madrid, Pozuelo de Alarcón, 28223 Madrid, Spain.
  • Atienza JM; Bioactive Surfaces S.L., C/Puerto de Navacerrada 18, 28260 Galapagar, Spain.
  • Elices M; Departamento de Ciencia de Materiales, ETSI Caminos, Canales y Puertos, Universidad Politécnica de Madrid, 28040 Madrid, Spain.
  • Guinea GV; Center for Biomedical Technology (CTB), Universidad Politécnica de Madrid, Pozuelo de Alarcón, 28223 Madrid, Spain.
  • Pérez-Rigueiro J; Bioactive Surfaces S.L., C/Puerto de Navacerrada 18, 28260 Galapagar, Spain.
Biomimetics (Basel) ; 9(4)2024 Mar 22.
Article em En | MEDLINE | ID: mdl-38667203
ABSTRACT
A versatile and robust procedure is developed that allows the identification of individual target molecules using antibodies bound to a DeepTipTM functionalized atomic-force microscopy probe. The model system used for the validation of this process consists of a biotinylated anti-lactate dehydrogenase antibody immobilized on a streptavidin-decorated AFM probe. Lactate dehydrogenase (LDH) is employed as target molecule and covalently immobilized on functionalized MicroDeckTM substrates. The interaction between sensor and target molecules is explored by recording force-displacement (F-z) curves with an atomic-force microscope. F-z curves that correspond to the genuine sensor-target molecule interaction are identified based on the following three criteria (i) number of peaks, (ii) value of the adhesion force, and (iii) presence or absence of the elastomeric trait. The application of these criteria leads to establishing seven groups, ranging from no interaction to multiple sensor-target molecule interactions, for which force-displacement curves are classified. The possibility of recording consistently single-molecule interaction events between an antibody and its specific antigen, in combination with the high proportion of successful interaction events obtained, increases remarkably the possibilities offered by affinity atomic-force microscopy for the characterization of biological and biomimetic systems from the molecular to the tissue scales.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article