Your browser doesn't support javascript.
loading
Radiation exposure of patients during endourological procedures.
De Coninck, Vincent; Mortiers, Xavier; Hendrickx, Laura; De Wachter, Stefan; Traxer, Olivier; Keller, Etienne X.
Afiliação
  • De Coninck V; Department of Urology, AZ Klina, Augustijnslei 100, 2930, Brasschaat, Belgium. vincent.de.coninck@klina.be.
  • Mortiers X; Young Academic Urologists (YAU), Urolithiasis & Endourology Working Party, 6846, Arnhem, The Netherlands. vincent.de.coninck@klina.be.
  • Hendrickx L; Department of Medicine, University of Antwerp, Campus Drie Eiken, Gebouw S, Universiteitsplein 1, 2610, Wilrijk, Belgium.
  • De Wachter S; Department of Medicine, University of Antwerp, Campus Drie Eiken, Gebouw S, Universiteitsplein 1, 2610, Wilrijk, Belgium.
  • Traxer O; Department of Medicine, University of Antwerp, Campus Drie Eiken, Gebouw S, Universiteitsplein 1, 2610, Wilrijk, Belgium.
  • Keller EX; GRC N°20, Groupe de Recherche Clinique Sur La Lithiase Urinaire, Hôpital Tenon, Sorbonne Université, Paris, France.
World J Urol ; 42(1): 266, 2024 Apr 27.
Article em En | MEDLINE | ID: mdl-38676726
ABSTRACT

PURPOSE:

Considering the existing gaps in the literature regarding patient radiation dose (RD) and its associated risks, a systematic review of the literature on RD was conducted, focusing on percutaneous nephrolithotomy (PCNL), extracorporeal shock wave lithotripsy (SWL), and ureteroscopy (URS).

METHODS:

Two authors conducted a literature search on PubMed, Web of Science, and Google Scholar to identify studies on RD during endourological procedures. Two thousand two hundred sixty-six articles were screened. Sixty-five publications met the inclusion criteria using the PRISMA standards.

RESULTS:

RD was generally highest for PCNL, reaching levels up to 33 mSv, 28,700 mGycm2, and 430.8 mGy. This was followed by SWL, with RD reaching up to 7.32 mSv, 13,082 mGycm2, and 142 mGy. URS demonstrated lower RD, reaching up to 6.07 mSv, 8920 mGycm2, and 46.99 mGy. Surgeon experience and case load were inversely associated with RD. Strategies such as optimizing fluoroscopy settings, implementing ultrasound (US), and following the ALARA (As Low As Reasonably Achievable) principle minimized RD.

CONCLUSIONS:

This is the first systematic review analyzing RD, which was generally highest during PCNL, followed by SWL and URS. There is no specific RD limit for these procedures. Implementation of strategies such as optimizing fluoroscopy settings, utilizing US, and adhering to the ALARA principle proved effective in reducing RD. However, further research is needed to explore the factors influencing RD, assess their impact on patient outcomes, and establish procedure-specific reference levels for RD.