Pain-free bite force in a healthy population: Within-session test-retest reliability in different sitting positions.
Mitchell, Andrew; Heales, Luke; Treleaven, Julia; Too, Brendan; Tyrrell, Ryan; Dinsdale, Alana.
Afiliação
  • Mitchell A; School of Health and Rehabilitation Sciences, The University of Queensland, St Lucia, Queensland, Australia.
  • Heales L; Physiotherapy Department, The Prince Charles Hospital, Chermside, Queensland, Australia.
  • Treleaven J; School of Health, Medical and Applied Sciences, Central Queensland University, Rockhampton, Queensland, Australia.
  • Too B; School of Health and Rehabilitation Sciences, The University of Queensland, St Lucia, Queensland, Australia.
  • Tyrrell R; School of Health and Rehabilitation Sciences, The University of Queensland, St Lucia, Queensland, Australia.
  • Dinsdale A; Joint Health Command, Serco, RAAF Base, Williamtown, New South Wales, Australia.
J Oral Rehabil ; 51(8): 1440-1449, 2024 Aug.
Article em En | MEDLINE | ID: mdl-38685714
ABSTRACT

BACKGROUND:

Pain-free bite force (PFBF) is a promising measure to evaluate bite function in temporomandibular disorders (TMDs), yet the reliability of the measure is unknown.

OBJECTIVES:

Establish the (1) within-session test-retest reliability of PFBF in a healthy population for a single and mean of three trials in supported and unsupported sitting; (2) standard error of measurement (SEM) and minimal detectable change (MDC).

METHODS:

Thirty healthy participants (n = 15 female, mean [SD] age = 34.4 [11.0] years) completed two sessions (30-60 min apart) comprising three PFBF trials on each side, in both supported and unsupported sitting, to provide data for 60 (30 participants × two sides) test-retest assessments. Test-retest reliability for the first trial and mean of three trials in each position were determined using intraclass correlation coefficients (ICCs), before calculating the corresponding SEM and MDC for males (M) and females (F) respectively.

RESULTS:

Within-session reliability was considered excellent for a single trial in supported sitting (ICC = 0.85; SEM M/F = 99/84 N; MDC M/F = 275/232 N) and unsupported sitting (ICC = 0.91; SEM M/F = 72/59 N, MDC M/F = 200/163 N), and for a mean of three trials in supported sitting (ICC = 0.89; SEM M/F = 66/79 N, MDC M/F = 182/220 N) and unsupported sitting (ICC = 0.92; SEM M/F = 64/59 N, MDC M/F = 177/164 N).

CONCLUSION:

Single and a mean of three trials in supported and unsupported sitting appear reliable methods to measure PFBF in a healthy population. Testing PFBF using a mean of three trials in unsupported sitting appears superior over other methods though due to higher test-retest reliability, and lower SEM and MDC. Future studies should examine the reliability of PFBF in TMD populations.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Força de Mordida / Voluntários Saudáveis / Postura Sentada Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Força de Mordida / Voluntários Saudáveis / Postura Sentada Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article