Your browser doesn't support javascript.
loading
The iPREFACE score is useful for predicting fetal acidemia: A retrospective cohort study of 113 patients who underwent emergency cesarean section for non-reassuring fetal status during labor.
Ito, Ayumu; Hayata, Eijiro; Kotaki, Hikari; Shimabukuro, Makiko; Takano, Mayumi; Nagasaki, Sumito; Nakata, Masahiko.
Afiliação
  • Ito A; Department of Obstetrics and Gynecology, Faculty of Medicine, Toho University, Tokyo, Japan (Drs Ito, Hayata, Kotaki, Shimabukuro, Takano, Nagasaki, and Nakata).
  • Hayata E; Department of Obstetrics and Gynecology, Toho University Omori Medical Center, Tokyo, Japan (Drs Ito, Hayata, Kotaki, Shimabukuro, Takano, Nagasaki, and Nakata).
  • Kotaki H; Department of Obstetrics and Gynecology, Faculty of Medicine, Toho University, Tokyo, Japan (Drs Ito, Hayata, Kotaki, Shimabukuro, Takano, Nagasaki, and Nakata).
  • Shimabukuro M; Department of Obstetrics and Gynecology, Toho University Omori Medical Center, Tokyo, Japan (Drs Ito, Hayata, Kotaki, Shimabukuro, Takano, Nagasaki, and Nakata).
  • Takano M; Department of Obstetrics and Gynecology, Faculty of Medicine, Toho University, Tokyo, Japan (Drs Ito, Hayata, Kotaki, Shimabukuro, Takano, Nagasaki, and Nakata).
  • Nagasaki S; Department of Obstetrics and Gynecology, Toho University Omori Medical Center, Tokyo, Japan (Drs Ito, Hayata, Kotaki, Shimabukuro, Takano, Nagasaki, and Nakata).
  • Nakata M; Department of Obstetrics and Gynecology, Faculty of Medicine, Toho University, Tokyo, Japan (Drs Ito, Hayata, Kotaki, Shimabukuro, Takano, Nagasaki, and Nakata).
AJOG Glob Rep ; 4(2): 100343, 2024 May.
Article em En | MEDLINE | ID: mdl-38699222
ABSTRACT

BACKGROUND:

The iPREFACE score may aid in predicting fetal acidemia and neonatal asphyxia in emergency cesarean and vaginal deliveries, which may improve labor management precision in the future.

OBJECTIVE:

This study aimed to assess the score use of the iPREFACE as an objective indicator of the need for rapid delivery in cases of repeated abnormal waveforms without concurrent indications for immediate medical intervention during labor. STUDY

DESIGN:

This retrospective cohort study was conducted among term (37+ 0 days to 41+6 days) singleton pregnant women who underwent emergency cesarean delivery owing to a nonreassuring fetal status. The integrated score index to predict fetal acidemia by intrapartum fetal heart rate monitoring-decision of emergency cesarean delivery score, calculated from a 30-minute cardiotocography waveform before the decision to perform emergency cesarean delivery, and the integrated score index to predict fetal acidemia by intrapartum fetal heart rate monitoring-removal of cardiotocography transducer score, calculated from a 30-minute cardiotocography waveform before cardiotocography transducer removal, were employed. The primary outcome was the assessment of the predictive ability of these scores for fetal acidemia, whereas the secondary outcomes were differences in umbilical artery blood gas findings and postnatal outcomes between the 2 groups, divided by the cutoff values of the integrated score index to predict fetal acidemia by intrapartum fetal heart rate monitoring-removal of cardiotocography score.

RESULTS:

The integrated score index to predict fetal acidemia by intrapartum fetal heart rate monitoring-decision of emergency cesarean delivery and integrated score index to predict fetal acidemia by intrapartum fetal heart rate monitoring-removal of cardiotocography transducer scores demonstrated the capability to predict an umbilical artery blood pH of <7.2. The integrated score index to predict fetal acidemia by intrapartum fetal heart rate monitoring-decision of emergency cesarean delivery and -removal of cardiotocography transducer score, with cutoff values of 37 and 46 points, respectively, exhibited an area under the receiver operating characteristic curve of 0.82 and 0.87, respectively. The integrated score index to predict fetal acidemia by intrapartum fetal heart rate monitoring-removal of cardiotocography transducer group with ≥46 points had higher incidence rates of an umbilical cord artery blood pH of <7.2, <7.1, and <7.0 and neonatal intensive care unit admissions for neonatal asphyxia.

CONCLUSION:

The integrated score index to predict fetal acidemia by intrapartum fetal heart rate monitoring, derived from cardiotocography during an emergency cesarean delivery, may enable clinicians to predict fetal acidemia in cases of nonreassuring fetal status. Improved prediction of fetal acidemia and facilitation of timely intervention hold promise for enhancing the outcomes of mothers and newborns during childbirth. Prospective studies are warranted to establish precise cutoff values and to validate the clinical application of these scores.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article