Clinical predictors of negative/equivocal SPECT imaging outcomes in primary hyperparathyroidism: Factors calling for 18F-choline-PET.
Am J Otolaryngol
; 45(4): 104315, 2024.
Article
em En
| MEDLINE
| ID: mdl-38701728
ABSTRACT
PURPOSE:
For minimally invasive surgery of parathyroid adenomas, exact localization diagnostics are essential. Main imaging modalities used for diagnostics are sonography, SPECT with/without CT (traditional imaging) and 18F-choline-PET. The aim of our study was to identify predictors for inconclusive SPECT imaging and subsequently determine in which cases 18F-choline-PET is needed.METHODS:
Retrospective analysis of 138 patients with histologically confirmed primary hyperparathyroidism (pHPT). After sonography, patients underwent SPECT or SPECT/CT imaging, with subsequent 18F-choline-PET in cases of disconcordant results. Logistic regression analysis was used to identify clinical and laboratory factors predictive for negative SPECT results.RESULTS:
Sensitivity rates for sonography, SPECT, SPECT/CT, and choline-PET were 47 %, 49 %, 71.7 %, and 97 %, respectively. Logistic regression revealed lower PTH levels (p < 0.001), presence of structural thyroid disease (p = 0.018), and negative sonography (p < 0.001) as predictive of negative/equivocal SPECT outcome. An additional traditional imaging CT scan to a SPECT enhanced detection odds, as did greater adenoma weight. Urolithiasis, osteoporosis, and calcium values as measurement of activity and duration of disease showed no significant association with the detection rate. Furthermore, our study demonstrated that 18F-choline-PET exhibited remarkable sensitivity in detecting adenomas among patients with negative/equivocal SPECT results.CONCLUSION:
Our study reveals potential predictive factors for a negative/equivocal SPECT outcome in pHPT. Identifying these factors might allow minimizing futile SPECT examinations and perhaps encourage timely utilization of 18F-choline-PET imaging. Our study reinforces the clinical significance of 18F-choline-PET, especially in complex cases with disconcordant results by conventional parathyroid imaging methods.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Neoplasias das Paratireoides
/
Tomografia Computadorizada de Emissão de Fóton Único
/
Colina
/
Hiperparatireoidismo Primário
Limite:
Adult
/
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Ano de publicação:
2024
Tipo de documento:
Article