Your browser doesn't support javascript.
loading
An electrochemical sensor based on molecularly imprinted poly(o-phenylenediamine) for the detection of thymol.
Dong, Jieming; Zhang, Hongyu; Ding, Zhixiang; Li, Junyao; Xu, Laidi; Kong, Yong; Zheng, Guojun.
Afiliação
  • Dong J; Jiangsu Key Laboratory of Advanced Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou, 213164, China.
  • Zhang H; Department of Clinical Laboratory, Changzhou No.3 People's Hospital, Changzhou, 213001, China.
  • Ding Z; Department of Clinical Laboratory, Changzhou Municipal Hospital of Traditional Chinese Medicine, Changzhou, 213003, China.
  • Li J; Jiangsu Key Laboratory of Advanced Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou, 213164, China.
  • Xu L; Jiangsu Key Laboratory of Advanced Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou, 213164, China.
  • Kong Y; Jiangsu Key Laboratory of Advanced Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou, 213164, China. Electronic address: yzkongyong@cczu.edu.cn.
  • Zheng G; Department of Clinical Laboratory, Changzhou No.3 People's Hospital, Changzhou, 213001, China. Electronic address: immu_zheng@126.com.
Anal Biochem ; 691: 115551, 2024 Aug.
Article em En | MEDLINE | ID: mdl-38702023
ABSTRACT
A molecularly imprinted electrochemical sensor was facilely fabricated for the detection of thymol (THY). o-Phenylenediamine (oPD) was used as the functional monomer and electropolymerized on the surface of the glassy carbon electrode (GCE) by using THY as the templates. After the THY templates were removed with 50 % (v/v) ethanol, imprinted cavities complementary to the templates were formed within the poly(o-phenylenediamine) (PoPD) films. The resultant molecularly imprinted PoPD/GCE (MI-PoPD/GCE) was used for the detection of THY, and a wide linear range from 0.5 to 100 µM with a low limit of detection (LOD) of 0.084 µM were obtained under the optimal conditions. The developed MI-PoPD/GCE also displays high selectivity, reproducibility and stability for THY detection. Finally, the content of THY in the real samples was accurately determined by the as-fabricated MI-PoPD/GCE, demonstrating its high practicability and reliability.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fenilenodiaminas / Timol / Impressão Molecular / Técnicas Eletroquímicas Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fenilenodiaminas / Timol / Impressão Molecular / Técnicas Eletroquímicas Idioma: En Ano de publicação: 2024 Tipo de documento: Article