Your browser doesn't support javascript.
loading
Transitioning from Triton X-100 to Tergitol 15-S-9: impacts on diagnostic assays using viral PCR sample solution.
Zorzoli, Azul; MacLean, Alasdair; Nicholson, Scott; Daniels, Alison; Hughes, Stephen; Bennet-Slater, Susan; Tait-Burkard, Christine; Sakka, Noha El; Gunson, Rory; Templeton, Kate.
Afiliação
  • Zorzoli A; Department of Clinical Microbiology, NHS Lothian, Edinburgh, UK.
  • MacLean A; West of Scotland Specialist Virology Centre, Glasgow Royal Infirmary, Glasgow, UK.
  • Nicholson S; West of Scotland Specialist Virology Centre, Glasgow Royal Infirmary, Glasgow, UK.
  • Daniels A; The Roslin Institute & Royal (Dick) School of Veterinary Studies, University of Edinburgh, Easter Bush, Midlothian, UK.
  • Hughes S; West of Scotland Specialist Virology Centre, Glasgow Royal Infirmary, Glasgow, UK.
  • Bennet-Slater S; West of Scotland Specialist Virology Centre, Glasgow Royal Infirmary, Glasgow, UK.
  • Tait-Burkard C; The Roslin Institute & Royal (Dick) School of Veterinary Studies, University of Edinburgh, Easter Bush, Midlothian, UK.
  • Sakka NE; Department of Medical Microbiology, NHS Grampian, Aberdeen, UK.
  • Gunson R; West of Scotland Specialist Virology Centre, Glasgow Royal Infirmary, Glasgow, UK.
  • Templeton K; Department of Clinical Microbiology, NHS Lothian, Edinburgh, UK.
Biotechniques ; 76(7): 295-298, 2024.
Article em En | MEDLINE | ID: mdl-38706171
ABSTRACT
In 2019, the European Union banned Triton X-100, a detergent widely used in laboratory diagnostics, including the Viral PCR Sample Solution (VPSS), and urged manufacturers to find environmentally sustainable alternatives. Tergitol 15-S-9 (VPSS2) has been proposed as an alternative surfactant. This multicenter study evaluated the effectiveness of VPSS2, a Tergitol-based viral solution, as a replacement for VPSS. Our results show the equivalent performance of VPSS2 to VPSS for nucleic acid extraction and viral stability over time at different temperatures. The new VPSS formulation was also tested against external quality assurance panels and clinical samples. The results of this work support adopting this modified viral PCR sample solution to replace Triton X-100-containing viral transport solutions.
The European Union has banned Triton X-100. All reagents containing it should be replaced. Could a new Viral PCR Sample Solution (VPSS) containing Tergitol 15-S-9 be a suitable replacement?