Your browser doesn't support javascript.
loading
Utility of metabolic ratios in the diagnosis of tumor Thrombus on F-18 FDG PET/CT.
Datta, Deepanksha; Kumar, Rajesh; Goel, Akhil Dhanesh.
Afiliação
  • Datta D; Department of Nuclear Medicine, All India Institute of Medical Sciences, Jodhpur, India.
  • Kumar R; Department of Nuclear Medicine, All India Institute of Medical Sciences, Jodhpur, India. rajesh.nmd@gmail.com.
  • Goel AD; Department of Community Medicine, All India Institute of Medical Sciences, Jodhpur, India.
EJNMMI Rep ; 8(1): 12, 2024 May 08.
Article em En | MEDLINE | ID: mdl-38748073
ABSTRACT

BACKGROUND:

This study aims to predict quantitative parameter in form of metabolic ratios to diagnose tumor thrombus on F-18 FDG PET/CT.

METHODS:

This is a retrospective study from Nuclear Medicine department at All India Institute of Medical Sciences, Jodhpur, India. Patients with malignancies who underwent F-18 FDG PET/CT in our department or images sent for review from February 2020 till September 2022 were screened for tumor thrombus that comprised study group. Control group had patients with malignancy and no imaging evidence of tumor thrombus. Metabolic activities (SUVmax) of tumor thrombus, liver and descending aorta in study group, and that of IVC, liver and descending aorta in control group were recorded. Metabolic ratios of tumor thrombus to liver (SUR L) and to aorta (SUR A) in study group, and IVC to liver (SUR* L) and to aorta (SUR*A) in control group were compared using receiver operator curves.

RESULTS:

Of 2277 studies screened, 12 had tumor thrombus. The most common primary malignant site and vessel involved were lung and IVC respectively. The median (IQR) SUR L, SUR A, SUR* L and SUR* A were 2.5 (3.25), 2.6  (6), 0.67 (0.18) and 1 (0.17) respectively. Area under ROC for SUR L and SUR A were 0.983 [95% CI 0.955-1.0] and 0.958 [95% CI 0.90-1.0] respectively. The ideal cut-off for SUR L was 0.953 (sensitivity 92.3%, specificity 98.0%) and for SUR A was 1.42 (sensitivity 84.6%, specificity 98.0%).

CONCLUSION:

Metabolic ratios of tumor thrombus to liver (SUR L) and aorta (SUR A) have good diagnostic performance and can be useful in studies with non-iodinated contrast CT.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article