Your browser doesn't support javascript.
loading
Automation improves the efficiency of weightbearing CT scan 3D volumetric assessments of the syndesmosis.
Ashkani-Esfahani, Soheil; Lucchese, Olivia; Bhimani, Rohan; Taseh, Atta; Waryasz, Gregory; Kerkhoffs, Gino M M; Maas, Mario; DiGiovanni, Christopher W; Guss, Daniel.
Afiliação
  • Ashkani-Esfahani S; Foot & Ankle Research and Innovation Lab (FARIL), Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA; Foot and Ankle Division, Department of Orthopaedic Surgery, Massachusetts General Hospital, Newton Wellesley Hospital, Harvard Medical Sch
  • Lucchese O; Foot & Ankle Research and Innovation Lab (FARIL), Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
  • Bhimani R; Foot & Ankle Research and Innovation Lab (FARIL), Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
  • Taseh A; Foot & Ankle Research and Innovation Lab (FARIL), Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA. Electronic address: ataseh@mgh.harvard.edu.
  • Waryasz G; Foot & Ankle Research and Innovation Lab (FARIL), Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA; Foot and Ankle Division, Department of Orthopaedic Surgery, Massachusetts General Hospital, Newton Wellesley Hospital, Harvard Medical Sch
  • Kerkhoffs GMM; Department of Orthopaedic Surgery and Sports Medicine, Amsterdam Movement Sciences, Amsterdam UMC, Location AMC, University of Amsterdam, Amsterdam, the Netherlands; Academic Center for Evidence based Sports medicine (ACES), Amsterdam UMC, Amsterdam, the Netherlands; Amsterdam Collaboration for Heal
  • Maas M; Academic Center for Evidence based Sports medicine (ACES), Amsterdam UMC, Amsterdam, the Netherlands; Amsterdam Collaboration for Health and Safety in Sports (ACHSS), International Olympic Committee (IOC) Research Center, Amsterdam UMC, Amsterdam, the Netherlands; Department of Radiology, Amsterdam
  • DiGiovanni CW; Foot & Ankle Research and Innovation Lab (FARIL), Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA; Foot and Ankle Division, Department of Orthopaedic Surgery, Massachusetts General Hospital, Newton Wellesley Hospital, Harvard Medical Sch
  • Guss D; Foot & Ankle Research and Innovation Lab (FARIL), Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA; Foot and Ankle Division, Department of Orthopaedic Surgery, Massachusetts General Hospital, Newton Wellesley Hospital, Harvard Medical Sch
Foot Ankle Surg ; 2024 May 22.
Article em En | MEDLINE | ID: mdl-38789380
ABSTRACT

BACKGROUND:

Weight-bearing CT (WBCT) 3D volumetric measurement has shown promising accuracy for the diagnosis of syndesmotic instability. However, these measurements are rather complex and time-consuming, rendering them a clinically unfavorable option. We hypothesized that automatized measurements would be more accurate and time-efficient than manual ones.

METHODS:

Thirty cases of intraoperatively confirmed syndesmotic instability along with thirty individuals with no injuries to the ankle joint were recruited as cases and controls, retrospectively. Two observers conducted the manual volumetric measurements two times, at a one-week interval. An automated algorithm for 3D WBCT measurements was developed to conduct the measurements on the axial images. The time spent on each method was recorded. Mann-Whitney U test was used to compare the values between human raters and computers. Inter- and intra-class reliability were calculated.

RESULTS:

The intra-class correlation coefficient was found to be "excellent" for the automated measurements (0.97) and "good" for the observers (0.75). Similarly, the Cronbach's alpha was shown to be higher for the computer (0.88) than the observers (0.60 and 0.62). The mean time spent on the measurements was different between human raters and the computer-assisted method (p < 0.001).

CONCLUSION:

Automated volumetric assessment of syndesmosis seems to be a faster and more reliable option than the manual one. We suggest future larger-scale prospective studies conducted under actual clinical circumstances for more definitive conclusions. LEVEL OF EVIDENCE Retrospective case-control study - Level 3.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article