Your browser doesn't support javascript.
loading
Influence of occlusal thickness on the fracture resistance of chairside milled lithium disilicate posterior full-coverage single-unit prostheses containing virgilite: A comparative in vitro study.
Jurado, Carlos A; Davila, Christian Edgar; Davila, Alexandra; Hernandez, Alfredo I; Odagiri, Yukari; Afrashtehfar, Kelvin I; Lee, Damian.
Afiliação
  • Jurado CA; Operative Dentistry Division, Department of General Dentistry, College of Dentistry, University of Tennessee Health Science Center, Memphis, Tennessee, USA.
  • Davila CE; Division of Prosthodontics, Department of Restorative Dental Sciences, University of Florida College of Dentistry, Gainesville, Florida, USA.
  • Davila A; Division of Prosthodontics, Department of Restorative Sciences, School of Dentistry, University of Alabama, Birmingham, Alabama, USA.
  • Hernandez AI; Division of Prosthodontics, Department of Restorative Dental Sciences, University of Florida College of Dentistry, Gainesville, Florida, USA.
  • Odagiri Y; A.T. Still University Arizona School of Dentistry and Oral Health, Mesa, Arizona, USA.
  • Afrashtehfar KI; Department of Operative Dentistry, School of Dentistry, Aichi Gakuin University, Nagoya, Japan.
  • Lee D; Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, Faculty of Medicine, University of Bern, Bern, Switzerland.
J Prosthodont ; 2024 May 24.
Article em En | MEDLINE | ID: mdl-38790151
ABSTRACT

PURPOSE:

To evaluate the fracture resistance of chairside computer-aided design and computer-aided manufacturing (CAD-CAM) lithium disilicate mandibular posterior crowns with virgilite of different occlusal thicknesses and compare them to traditional lithium disilicate crowns. MATERIALS AND

METHODS:

Seventy-five chairside CAD-CAM crowns were fabricated for mandibular right first molars, 60 from novel lithium disilicate with virgilite (CEREC Tessera, Dentsply Sirona), and 15 from traditional lithium disilicate (e.max CAD, Ivoclar Vivadent). These crowns were distributed across five groups based on occlusal thickness and

material:

Group 1 featured CEREC Tessera crowns with 0.8 mm thickness, Group 2 had 1.0 mm thickness, Group 3 had 1.2 mm thickness, Group 4 with 1.5 mm thickness, and Group 5 included e.max CAD crowns with 1.0 mm thickness. These crowns were luted onto 3D-printed resin dies using Multilink Automix resin cement (Ivoclar Vivadent). Subsequently, they underwent cyclic loading (2,000,000 cycles at 1 Hz with a 275 N force) and loading until fracture. Scanning electron microscopy (SEM) assessed the fractured specimens. Statistical analysis involved one-way ANOVA and the Kruskal-Wallis Test (α = 0.05).

RESULTS:

Fracture resistance varied significantly (<0.001) across mandibular molar crowns fabricated from chairside CAD-CAM lithium disilicate containing virgilite, particularly between crowns with 0.8 mm and those with 1.2 and 1.5 mm occlusal thickness. However, no significant differences were found when comparing crowns with 1, 1.2, and 1.5 mm thicknesses. CEREC Tessera crowns with 1.5 mm thickness exhibited the highest resistance (2119 N/mm2), followed by those with 1.2 mm (1982 N/mm2), 1.0 mm (1763 N/mm2), and 0.8 mm (1144 N/mm2) thickness, whereas e.max CAD crowns with 1.0 mm occlusal thickness displayed the lowest resistance (814 N/mm2).

CONCLUSIONS:

The relationship between thickness and fracture resistance in the virgilite lithium disilicate full-coverage crowns was directly proportional, indicating that increased thickness corresponded to higher fracture resistance. No significant differences were noted among crowns with thicknesses ranging from 1 to 1.5 mm. This novel ceramic exhibited superior fracture resistance compared to traditional lithium disilicate.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article