Your browser doesn't support javascript.
loading
Embolization of Patent Foramen Ovale Closure Device-Rare Complication and Unique Management Approach.
Kovacevic, Mila; Atanaskovic, Marko; Obradovic, Katarina; Todic, Mirko; Crnomarkovic, Branislav; Bjelobrk, Marija; Bjelic, Snezana; Cankovic, Milenko; Milovancev, Aleksandra; Srdanovic, Ilija.
Afiliação
  • Kovacevic M; Faculty of Medicine, University of Novi Sad, 21000 Novi Sad, Serbia.
  • Atanaskovic M; Institute of Cardiovascular Diseases of Vojvodina, 21204 Sremska Kamenica, Serbia.
  • Obradovic K; Faculty of Medicine, University of Novi Sad, 21000 Novi Sad, Serbia.
  • Todic M; Faculty of Medicine, University of Novi Sad, 21000 Novi Sad, Serbia.
  • Crnomarkovic B; Faculty of Medicine, University of Novi Sad, 21000 Novi Sad, Serbia.
  • Bjelobrk M; Institute of Cardiovascular Diseases of Vojvodina, 21204 Sremska Kamenica, Serbia.
  • Bjelic S; Faculty of Medicine, University of Novi Sad, 21000 Novi Sad, Serbia.
  • Cankovic M; Institute of Cardiovascular Diseases of Vojvodina, 21204 Sremska Kamenica, Serbia.
  • Milovancev A; Faculty of Medicine, University of Novi Sad, 21000 Novi Sad, Serbia.
  • Srdanovic I; Institute of Cardiovascular Diseases of Vojvodina, 21204 Sremska Kamenica, Serbia.
Medicina (Kaunas) ; 60(5)2024 Apr 26.
Article em En | MEDLINE | ID: mdl-38792900
ABSTRACT
Percutaneous closure of the patent foramen ovale (PFO) is generally regarded as a safe and effective procedure, indicated in patients with a prior PFO-associated stroke. While it is highly safe, rarely, it could be accompanied by a migration of the device, mainly caused by the interplay of a specific PFO morphology and inappropriate device sizing. Herein, we outline a seldom-observed complication of an unintentional detachment of the PFO closure device during implantation, leading to its migration into the abdominal aorta, and a unique management approach. Due to the inability to recapture the occluder with a snare, which is considered to be a mainstay of endovascular retrieval methods, two coronary guidewires were maneuvered through the mesh of the occluder and then captured with a snare proximally to the occluder. This innovative dual-wire-snare system was carefully pulled to the common femoral artery, a position deemed suitable for surgical extraction via arteriotomy, which was achieved successfully.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Forame Oval Patente / Dispositivo para Oclusão Septal Limite: Female / Humans / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Forame Oval Patente / Dispositivo para Oclusão Septal Limite: Female / Humans / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article