Your browser doesn't support javascript.
loading
Bicuspid valve CT registry of balloon-expandable TAVR: BETTER TAVR registry.
Chavarria, Jorge; Falcao, Felipe; AlRaddadi, Hatim; Aziz, Amir; Dick, Alexander; Chung, Kevin; Meier, David; Sathananthan, Janar; Ali, Noman; Um, Kevin John; Velianou, James; Natarajan, Madhu; Jaffer, Iqbal; Wood, David; Fam, Neil; Sheth, Tej.
Afiliação
  • Chavarria J; McMaster University and Hamilton Health Sciences, Hamilton, Canada.
  • Falcao F; McMaster University and Hamilton Health Sciences, Hamilton, Canada.
  • AlRaddadi H; McMaster University and Hamilton Health Sciences, Hamilton, Canada.
  • Aziz A; McMaster University and Hamilton Health Sciences, Hamilton, Canada.
  • Dick A; Ottawa Heart Institute, Ottawa, Canada.
  • Chung K; Ottawa Heart Institute, Ottawa, Canada.
  • Meier D; Centre for Cardiovascular Innovation, St. Paul's and Vancouver General Hospital, University of British Columbia, Vancouver, Canada.
  • Sathananthan J; Centre for Cardiovascular Innovation, St. Paul's and Vancouver General Hospital, University of British Columbia, Vancouver, Canada.
  • Ali N; St. Michael's Hospital, University of Toronto, Toronto, Canada.
  • Um KJ; Population Health Research Institute, Hamilton, Canada.
  • Velianou J; McMaster University and Hamilton Health Sciences, Hamilton, Canada.
  • Natarajan M; McMaster University and Hamilton Health Sciences, Hamilton, Canada.
  • Jaffer I; McMaster University and Hamilton Health Sciences, Hamilton, Canada.
  • Wood D; Centre for Cardiovascular Innovation, St. Paul's and Vancouver General Hospital, University of British Columbia, Vancouver, Canada.
  • Fam N; St. Michael's Hospital, University of Toronto, Toronto, Canada.
  • Sheth T; McMaster University and Hamilton Health Sciences, Hamilton, Canada.
Catheter Cardiovasc Interv ; 104(1): 105-114, 2024 Jul.
Article em En | MEDLINE | ID: mdl-38819623
ABSTRACT

BACKGROUND:

The anatomic substrate of bicuspid valves may lead to suboptimal TAVR stent expansion and geometry.

AIM:

We evaluated determinants of stent geometry in bicuspid valves treated with Sapien transcatheter aortic valve replacement (TAVR) valves.

METHODS:

A multicenter retrospective registry of patients (February 2019 to August 2022) who underwent post-TAVR computed tomography to determine stent area (vs. nominal valve area) and stent ellipticity (maximum diameter/minimum diameter). Predictors of relative stent expansion (minimum area/average of inflow + outflow area) and stent ellipticity were evaluated in a multivariable regression model, including valve calcium volume (indexed by annular area), presence of raphe calcium, sinus diameters indexed by area-derived annular diameter, and performance of pre-dilation and post-dilation.

RESULTS:

The registry enrolled 101 patients from four centers. The minimum stent area (vs. nominal area) was 88.1%, and the maximum ellipticity was 1.10, with both observed near the midframe of the valve in all cases. Relative stent expansion ≥90% was observed in 64/101 patients. The only significant predictor of relative stent expansion ≥90% was the performance of post-dilation (OR 4.79, p = 0.018). Relative stent expansion ≥90% was seen in 86% of patients with post-dilation compared to 57% without (p < 0.001). The stent ellipticity ≥1.1 was observed in 47/101 patients. The significant predictors of stent ellipticity ≥1.1 were the indexed maximum sinus diameter (OR 0.582, p = 0.021) and indexed intercommisural diameter at 4 mm (OR 2.42, p = 0.001). Stent expansion has a weak negative correlation with post-TAVR mean gradient (r = -0.324, p < 0.001).

CONCLUSION:

Relative stent expansion ≥90% was associated with the performance of post-dilation, and stent ellipticity ≥1.1 was associated with indexed intercommisural diameter and indexed maximum sinus diameter. Further studies to determine optimal deployment strategies in bicuspid valves are needed.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Desenho de Prótese / Próteses Valvulares Cardíacas / Sistema de Registros / Substituição da Valva Aórtica Transcateter Limite: Aged / Aged80 / Female / Humans / Male País/Região como assunto: America do norte Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Desenho de Prótese / Próteses Valvulares Cardíacas / Sistema de Registros / Substituição da Valva Aórtica Transcateter Limite: Aged / Aged80 / Female / Humans / Male País/Região como assunto: America do norte Idioma: En Ano de publicação: 2024 Tipo de documento: Article