High-sensitivity strain sensor based on an asymmetric tapered air microbubble Fabry-Pérot interferometer with an ultrathin wall.
Opt Express ; 32(11): 19057-19068, 2024 May 20.
Article em En | MEDLINE | ID: mdl-38859049
ABSTRACT
A Fabry-Pérot interferometer (FPI) with an asymmetric tapered structure and air microbubble with an ultrathin wall is designed for high-sensitivity strain measurement. The sensor contains an air microbubble formed by two single-mode fibers (SMF) prepared by fusion splicer arc discharge, and a taper is applied to one side of the air microbubble with a wall thickness of 3.6 µm. In this unique asymmetric structure, the microbubble is more easily deformed under stress, and the strain sensitivity of the sensor is up to 15.89 pm/µÉ› as evidenced by experiments.The temperature sensitivity and cross-sensitivity of the sensor are 1.09 pm/°C and 0.069 µÉ›/°C in the temperature range of 25-200°C, respectively, thus reducing the measurement error arising from temperature variations. The sensor has notable virtues such as high strain sensitivity, low-temperature sensitivity, low-temperature cross-sensitivity, simple and safe process preparation, and low cost. Experiments confirm that the sensor has good stability and repeatability, and it has high commercial potential, especially strain measurements in complex environments.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article