Your browser doesn't support javascript.
loading
Electrochemical Determination of Uric Acid Using a Nanocomposite Electrode with Molybdenum Disulfide/Multiwalled Carbon Nanotubes (MoS2@MWCNT).
Penagos-Llanos, Johisner; Segura, Rodrigo; de la Vega, Amaya Paz; Pichun, Bryan; Liendo, Fabiana; Riesco, Fernando; Nagles, Edgar.
Afiliação
  • Penagos-Llanos J; Departamento de Química de los Materiales, Facultad de Química y Biología, Universidad de Santiago de Chile (USACH), Santiago 9170002, Chile.
  • Segura R; Departamento de Química de los Materiales, Facultad de Química y Biología, Universidad de Santiago de Chile (USACH), Santiago 9170002, Chile.
  • de la Vega AP; Departamento de Química de los Materiales, Facultad de Química y Biología, Universidad de Santiago de Chile (USACH), Santiago 9170002, Chile.
  • Pichun B; Departamento de Química de los Materiales, Facultad de Química y Biología, Universidad de Santiago de Chile (USACH), Santiago 9170002, Chile.
  • Liendo F; Departamento de Química de los Materiales, Facultad de Química y Biología, Universidad de Santiago de Chile (USACH), Santiago 9170002, Chile.
  • Riesco F; Facultad de Química e Ingeniería Química, Universidad Nacional Mayor de San Marcos, Lima 15081, Peru.
  • Nagles E; Facultad de Química e Ingeniería Química, Universidad Nacional Mayor de San Marcos, Lima 15081, Peru.
Nanomaterials (Basel) ; 14(11)2024 May 30.
Article em En | MEDLINE | ID: mdl-38869583
ABSTRACT
This paper presents an application for a molybdenum disulfide nanomaterial with multiwalled carbon nanotubes (MoS2@MWCNT/E) in a modified electrode substrate for the detection of uric acid (UA). The modified electrode generates a substantial three-fold increase in the anodic peak current for UA compared to the unmodified MWCNT electrode (MWCNT/E). The MoS2@MWCNT/E surface was characterized by cyclic voltammetry (CV), scanning electron microscopy (SEM), energy-dispersive spectroscopy (EDS) and electrochemical impedance spectroscopy (EIS). The achieved detection limit stood at 0.04 µmol/L, with a relative standard deviation (RSD) of 2.0% (n = 10). The method's accuracy, assessed through relative error and percent recovery, was validated using a urine standard solution spiked with known quantities of UA.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article