Your browser doesn't support javascript.
loading
Detection and Exclusion of False-Positive Molecular Formula Assignments via Mass Error Distributions in UHR Mass Spectra of Natural Organic Matter.
Gao, Shuxian; Jennings, Elaine K; Han, Limei; Koch, Boris P; Herzsprung, Peter; Lechtenfeld, Oliver J.
Afiliação
  • Gao S; Department Environmental Analytical Chemistry, Research Group BioGeoOmics, Helmholtz Centre for Environmental Research─UFZ, Permoserstr. 15, Leipzig D-04318, Germany.
  • Jennings EK; Department Environmental Analytical Chemistry, Research Group BioGeoOmics, Helmholtz Centre for Environmental Research─UFZ, Permoserstr. 15, Leipzig D-04318, Germany.
  • Han L; Department Environmental Analytical Chemistry, Research Group BioGeoOmics, Helmholtz Centre for Environmental Research─UFZ, Permoserstr. 15, Leipzig D-04318, Germany.
  • Koch BP; Department of Biosciences, Ecological Chemistry, Helmholtz Centre for Polar and Marine Research─AWI, Am Handelshafen 12, Bremerhaven D-27570, Germany.
  • Herzsprung P; University of Applied Sciences, An der Karlstadt 8, Bremerhaven 27568, Germany.
  • Lechtenfeld OJ; Department Lake Research, Helmholtz Centre for Environmental Research─UFZ, Brückstr. 3a, Magdeburg D-39114, Germany.
Anal Chem ; 96(25): 10210-10218, 2024 Jun 25.
Article em En | MEDLINE | ID: mdl-38869925
ABSTRACT
Ultrahigh resolution mass spectrometry (UHRMS) routinely detects and identifies thousands of mass peaks in complex mixtures, such as natural organic matter (NOM) and petroleum. The assignment of several chemically plausible molecular formulas (MFs) for a single accurate mass still poses a major problem for the reliable interpretation of NOM composition in a biogeochemical context. Applying sensible chemical rules for MF validation is often insufficient to eliminate multiple assignments (MultiAs)─especially for mass peaks with low abundance or if ample heteroatoms or isotopes are included - and requires manual inspection or expert judgment. Here, we present a new approach based on mass error distributions for the identification of true and false assignments among MultiAs. To this end, we used the mass error in millidalton (mDa), which was superior to the commonly used relative mass error in ppm. We developed an automatic workflow to group MultiAs based on their shared formula units and Kendrick mass defect values and to evaluate the mass error distribution. In this way, the number of valid assignments of chlorinated disinfection byproducts was increased by 8-fold as compared to only applying 37Cl/35Cl isotope ratio filters. Likewise, phosphorus-containing MFs can be differentiated against chlorine-containing MFs with high confidence. Further, false assignments of highly aromatic sulfur-containing MFs ("black sulfur") to sodium adducts in negative ionization mode can be excluded by applying our approach. Overall, MFs for mass peaks that are close to the detection limit or where naturally occurring isotopes are rare (e.g., 15N) or absent (e.g., P and F) can now be validated, substantially increasing the reliability of MF assignments and broadening the applicability of UHRMS analysis to even more complex samples and processes.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article