Your browser doesn't support javascript.
loading
Visual and Quantitative Evaluation of Low-Concentration Bismuth in Dual-Contrast Imaging of Iodine and Bismuth Using Clinical Photon-Counting CT.
Ataei, Afrouz; Vasan, Vasantha; Soesbe, Todd C; Brewington, Cecelia C; Zhou, Zhongxing; Yu, Lifeng; Hallam, Kristina A; Ren, Liqiang.
Afiliação
  • Ataei A; Department of Radiology, UT Southwestern Medical Center, Dallas, TX 75390, USA.
  • Vasan V; Department of Radiology, UT Southwestern Medical Center, Dallas, TX 75390, USA.
  • Soesbe TC; Department of Radiology, UT Southwestern Medical Center, Dallas, TX 75390, USA.
  • Brewington CC; Department of Radiology, UT Southwestern Medical Center, Dallas, TX 75390, USA.
  • Zhou Z; Department of Radiology, Mayo Clinic, Rochester, MN 55905, USA.
  • Yu L; Department of Radiology, Mayo Clinic, Rochester, MN 55905, USA.
  • Hallam KA; Siemens Medical Solutions USA Inc., Malvern, PA 19355, USA.
  • Ren L; Department of Radiology, UT Southwestern Medical Center, Dallas, TX 75390, USA.
Sensors (Basel) ; 24(11)2024 Jun 01.
Article em En | MEDLINE | ID: mdl-38894358
ABSTRACT
Simultaneous dual-contrast imaging of iodine and bismuth has shown promise in prior phantom and animal studies utilizing spectral CT. However, it is noted that in previous studies, Pepto-Bismol has frequently been employed as the source of bismuth, exceeding the recommended levels for human subjects. This investigation sought to assess the feasibility of visually differentiating and precisely quantifying low-concentration bismuth using clinical dual-source photon-counting CT (PCCT) in a scenario involving both iodinated and bismuth-based contrast materials. Four bismuth samples (0.6, 1.3, 2.5, and 5.1 mg/mL) were prepared using Pepto-Bismol, alongside three iodine rods (1, 2, and 5 mg/mL), inserted into multi-energy CT phantoms with three different sizes, and scanned on a PCCT system at three tube potentials (120, 140, and Sn140 kV). A generic image-based three-material decomposition method generated iodine and bismuth maps, with mean mass concentrations and noise levels measured. The root-mean-square errors for iodine and bismuth determined the optimal tube potential. The tube potential of 140 kV demonstrated optimal quantification performance when both iodine and bismuth were considered. Distinct differentiation of iodine rods with all three concentrations and bismuth samples with mass concentrations ≥ 1.3 mg/mL was observed across all phantom sizes at the optimal kV setting.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Bismuto / Tomografia Computadorizada por Raios X / Fótons / Imagens de Fantasmas / Meios de Contraste / Iodo Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Bismuto / Tomografia Computadorizada por Raios X / Fótons / Imagens de Fantasmas / Meios de Contraste / Iodo Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article