Your browser doesn't support javascript.
loading
A comparative study on 3D printing-assisted arthroscopic IDEAL point femoral tunnel positioning for anterior cruciate ligament reconstruction versus conventional arthroscopic positioning.
Chen, Tiezhu; Chen, Junjie; Li, Xiaosheng; He, Yinhao; Peng, Qiang; Chen, Hongwen.
Afiliação
  • Chen T; Department of Orthopedics, Hunan Provincial People's Hospital, The First Affiliated Hospital of Hunan Normal University), Changsha, Hunan, 410002, China.
  • Chen J; Clinical Research Center of Sports Medicine in Hunan Province, Changsha, 410002, China.
  • Li X; Department of Orthopedics, Longhui People's Hospital, Longhui, Hunan, 422200, China.
  • He Y; Department of Orthopedics, Hunan Provincial People's Hospital, The First Affiliated Hospital of Hunan Normal University), Changsha, Hunan, 410002, China. lxsld2009@163.com.
  • Peng Q; Clinical Research Center of Sports Medicine in Hunan Province, Changsha, 410002, China. lxsld2009@163.com.
  • Chen H; Department of Orthopedics, Hunan Provincial People's Hospital, The First Affiliated Hospital of Hunan Normal University), Changsha, Hunan, 410002, China.
BMC Musculoskelet Disord ; 25(1): 481, 2024 Jun 19.
Article em En | MEDLINE | ID: mdl-38898426
ABSTRACT

BACKGROUND:

This study aimed to investigate the feasibility and precision of using a 3D-printed template for femoral tunnel placement in guiding the optimal positioning of the Internal anatomical stop and Low tension maintenance (IDEAL) bone tunnel during single-bundle anterior cruciate ligament (ACL) reconstruction.

METHODS:

A retrospective analysis was conducted on 40 patients who underwent arthroscopic single-bundle ACL reconstruction at our hospital between April 2021 and November 2021. In the direct vision group, the IDEAL bone tunnel was positioned using radiofrequency localization directly visualized at the stump. In the 3D-printed positioning group, preoperative CT scans and Digital Imaging and Communications in Medicine (DICOM) data were employed. Following the Quadrant method by Bernard, the femoral tunnel's depth was set at 25% and its height at 29%. Postoperative plain CT scans enabled the reconstruction of 3D models for both groups. The accuracy of femoral tunnel placement was then compared.

RESULTS:

The central locations of the bone tunnels in the direct vision group were at a mean depth of 25.74 ± 1.84% and a height of 29.22 ± 2.97%. In the 3D printing localization group, these values were 25.39 ± 2.98% for depth and 28.89 ± 2.50% for height, respectively. No significant differences were found in tunnel positioning between the groups. Both groups demonstrated statistically significant improvements in International Knee Documentation Committee Subjective Knee Form (IKDC) and Lysholm scores postoperatively, with no significant differences observed 12 months post-surgery.

CONCLUSION:

The findings of this study suggest that 3D printing-assisted arthroscopic IDEAL point femoral tunnel positioning and conventional arthroscopic positioning are feasible and effective for ACL reconstruction. Using 3D printing technology to design femoral anchor points in ACL reconstruction allows for the customization of anterior fork reconstruction and precise bone tunnel positioning, supporting the goal of individualized and accurate reconstruction.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroscopia / Fêmur / Reconstrução do Ligamento Cruzado Anterior / Impressão Tridimensional Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroscopia / Fêmur / Reconstrução do Ligamento Cruzado Anterior / Impressão Tridimensional Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article