Your browser doesn't support javascript.
loading
In situ growth of dual-responsive polymer as coating for open tubular capillary electrochromatographic separation of epimedins.
Ali, Nasir; Yutong, Liu; Wang, Fuyi; Qi, Li.
Afiliação
  • Ali N; Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Beijing National Laboratory of Molecular Sciences, Chinese Academy of Sciences, Beijing, 100190, China.
  • Yutong L; School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing, 100049, China.
  • Wang F; Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Beijing National Laboratory of Molecular Sciences, Chinese Academy of Sciences, Beijing, 100190, China.
  • Qi L; School of Pharmacy, Xinxiang Medical University, Xinxiang, 453003, China.
Anal Bioanal Chem ; 416(20): 4571-4580, 2024 Aug.
Article em En | MEDLINE | ID: mdl-38902347
ABSTRACT
Recently, open tubular capillary electrochromatography (OT-CEC) has captured considerable interest; its efficient separation capability hinges on the interactions between analytes and polymer coatings. However, in situ growth of stimuli-responsive polymers as coatings has been rarely studied and is crucial for expanding the OT-CEC technique and its application. Herein, following poly(styrene-maleicanhydride) (PSM) chemically bonded onto the inner surface of the capillary, a dual pH/temperature stimuli-responsive block copolymer, P(SMN-COOH), was prepared by in situ polymerizing poly(N-isopropylacrylamide) carboxylic acid terminated [P(N-COOH)] in PSM. An OT-CEC protocol was first explored using the coated capillary for epimedins separation. As a proof of concept, the developed OT-CEC system facilitated hydrogen bonding and tuning the hydrophilic/hydrophobic interactions between the test analytes and the P(SMN-COOH) coating by varying buffer pH and environmental temperature. Four epimedins with similar chemical structures were baseline separated under 40 °C at pH 10.0, exhibiting dramatical improvement in separation efficiency in comparison to its performance under 25 °C at pH 4.0. In addition, the coated capillary showed good repeatability and reusability with relative standard deviations for migration time and peak area between 0.7 and 1.7% and between 2.9 and 4.6%, respectively, and no significant changes after six runs. This work introduces a paradigm for efficient OT-CEC separation of herbal medicines through adjusting the interactions between analytes and smart polymer coatings, addressing polymer coating design and OT-CEC challenges.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article