Your browser doesn't support javascript.
loading
DNA tetrahedral scaffold-corbelled self-feedback circuit for dual-mode ratiometric biosensing with Ru@COF-LZU1 accelerator.
Zhang, Yan; Guo, Yuehua; Yang, Huan; Miao, Xiangmin; Feng, Qiumei.
Afiliação
  • Zhang Y; Research Center of Clinical Medicine, Affiliated Hospital of Nantong University, Nantong, 226001, PR China. Electronic address: yyanzh1215@163.com.
  • Guo Y; Research Center of Clinical Medicine, Affiliated Hospital of Nantong University, Nantong, 226001, PR China.
  • Yang H; School of Chemistry and Materials Science, Jiangsu Normal University, Xuzhou, 221116, PR China.
  • Miao X; School of Life Science, Jiangsu Normal University, Xuzhou, 221116, PR China.
  • Feng Q; School of Chemistry and Materials Science, Jiangsu Normal University, Xuzhou, 221116, PR China. Electronic address: fengqiumei@jsnu.edu.cn.
Biosens Bioelectron ; 261: 116520, 2024 Oct 01.
Article em En | MEDLINE | ID: mdl-38924812
ABSTRACT
Sensitive, reliable, and specific detection of microRNAs (miRNAs) is a key objective for disease diagnosis and prognosis. Here, a ratiometric fluorescent/electrochemiluminescent (FL/ECL) sensor was designed for the dual-mode detection of miRNA-122, a hepatocellular carcinoma biomarker. The strong ECL emission was achieved from imine-linked covalent organic framework (COF-LZU1) accelerator enriched Ru(bpy)32+ molecules (Ru@COF-LZU1), which was applied as a delimited reaction micro-reactor to enhance ECL emission. Impressively, to construct an efficient sensing platform, self-feedback circuit was grafted at the vertex of DNA tetrahedral scaffold (DTS), which could provide a solution-phase-like environment and transform miRNA-122 into abundant single-stranded DNAs on the disposable electrode. Simultaneously, the carboxyfluorescein (FAM) tagged DNA segment was cleaved and released into the reaction solution, bringing in the recovery of FL response (FL on). Finally, the introduction of glucose oxidase (GOD) could generate H2O2 by in situ catalyzing GOD to glucose, resulting in the decrease of ECL signal (ECL off). Relying on FL/ECL ratio value, miRNA-122 was quantified with high sensitivity, well selectivity, stability and favorable practicability, suggesting that the proposed biosensor hold great potential for clinical diagnosis.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / MicroRNAs / Estruturas Metalorgânicas Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / MicroRNAs / Estruturas Metalorgânicas Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article