Prediction of the Hamstring Graft Size for ACL Reconstruction Using Different Axial Layers in Preoperative MRI.
Mayr, Moritz Florian; Siegel, Markus; Taghizadeh, Elham; Obid, Peter; Schmal, Hagen; Izadpanah, Kaywan.
Afiliação
  • Mayr MF; Department of Orthopedic Surgery and Traumatology, Freiburg University Hospital, Albert Ludwigs University Freiburg, Hugstetter Straße 55, 79106 Freiburg, Germany.
  • Siegel M; Department of Orthopedic Surgery and Traumatology, Freiburg University Hospital, Albert Ludwigs University Freiburg, Hugstetter Straße 55, 79106 Freiburg, Germany.
  • Taghizadeh E; Fraunhofer Institute for Digital Medicine MEVIS, Max-von-Laue-Str. 2, 28359 Bremen, Germany.
  • Obid P; Department of Orthopedic Surgery and Traumatology, Freiburg University Hospital, Albert Ludwigs University Freiburg, Hugstetter Straße 55, 79106 Freiburg, Germany.
  • Schmal H; Department of Orthopedic Surgery and Traumatology, Freiburg University Hospital, Albert Ludwigs University Freiburg, Hugstetter Straße 55, 79106 Freiburg, Germany.
  • Izadpanah K; Department of Orthopedic Surgery, University Hospital Odense, Sdr. Boulevard 29, 5000 Odense, Denmark.
J Pers Med ; 14(6)2024 May 29.
Article em En | MEDLINE | ID: mdl-38929803
ABSTRACT

BACKGROUND:

In ACL reconstruction, it is desirable to assess preoperatively whether a sufficient graft diameter can be achieved with the planned tendon graft. The present study investigated the effect of the location of the cross-sectional area (CSA) measurement of the hamstring tendons in preoperative MRI on the correlation of the CSA with the intraoperative graft diameter. In addition, we analyzed whether the measurement results of examiners with different skill levels were comparable.

METHODS:

A total of 32 subjects undergoing a single bundle ACL reconstruction using an autologous ipsilateral quadrupled hamstring graft (STGT) were included. The CSA of the semitendinosus and gracilis tendon was determined in preoperative MRI on six defined levels by three examiners. The intraclass correlation coefficient between the measurements of these observers was determined. The correlation between the sum of the CSA of both tendons (CSA STGT) and the graft diameter was investigated.

RESULTS:

The interrater reliability was excellent on most of the investigated levels. A significant correlation between CSA STGT and the graft diameter was seen on all levels. The strongest correlation was found on the level 10 mm above the joint line.

CONCLUSIONS:

The measurement of the CSA STGT in the preoperative MRI 10 mm above the joint line enabled a good assessment of the achievable graft diameter in ACL reconstruction, independent of the examiners' training level.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article