Your browser doesn't support javascript.
loading
Terahertz Sensing of L-Valine and L-Phenylalanine Solutions.
Shu, Jingyi; Zhou, Xinli; Hao, Jixuan; Zhao, Haochen; An, Mingming; Zhang, Yichen; Zhao, Guozhong.
Afiliação
  • Shu J; Beijing Key Laboratory for THz Spectroscopy and Imaging, Key Laboratory of THz Optoelectronics, Ministry of Education, Department of Physics, Capital Normal University, Beijing 100048, China.
  • Zhou X; Beijing Key Laboratory for THz Spectroscopy and Imaging, Key Laboratory of THz Optoelectronics, Ministry of Education, Department of Physics, Capital Normal University, Beijing 100048, China.
  • Hao J; Beijing Key Laboratory for THz Spectroscopy and Imaging, Key Laboratory of THz Optoelectronics, Ministry of Education, Department of Physics, Capital Normal University, Beijing 100048, China.
  • Zhao H; Beijing Key Laboratory for THz Spectroscopy and Imaging, Key Laboratory of THz Optoelectronics, Ministry of Education, Department of Physics, Capital Normal University, Beijing 100048, China.
  • An M; Beijing Key Laboratory for THz Spectroscopy and Imaging, Key Laboratory of THz Optoelectronics, Ministry of Education, Department of Physics, Capital Normal University, Beijing 100048, China.
  • Zhang Y; Beijing Key Laboratory for THz Spectroscopy and Imaging, Key Laboratory of THz Optoelectronics, Ministry of Education, Department of Physics, Capital Normal University, Beijing 100048, China.
  • Zhao G; Beijing Key Laboratory for THz Spectroscopy and Imaging, Key Laboratory of THz Optoelectronics, Ministry of Education, Department of Physics, Capital Normal University, Beijing 100048, China.
Sensors (Basel) ; 24(12)2024 Jun 12.
Article em En | MEDLINE | ID: mdl-38931580
ABSTRACT
To detect and differentiate two essential amino acids (L-Valine and L-Phenylalanine) in the human body, a novel asymmetrically folded dual-aperture metal ring terahertz metasurface sensor was designed. A solvent mixture of water and glycerol with a volume ratio of 28 was proposed to reduce the absorption of terahertz waves by reducing the water content. A sample chamber with a controlled liquid thickness of 15 µm was fabricated. And a terahertz time-domain spectroscopy (THz-TDS) system, which is capable of horizontally positioning the samples, was assembled. The results of the sensing test revealed that as the concentration of valine solution varied from 0 to 20 mmol/L, the sensing resonance peak shifted from 1.39 THz to 1.58 THz with a concentration sensitivity of 9.98 GHz/mmol∗L-1. The resonance peak shift phenomenon in phenylalanine solution was less apparent. It is assumed that the coupling enhancement between the absorption peak position of solutes in the solution and the sensing peak position amplified the terahertz localized electric field resonance, which resulted in the increase in frequency shift. Therefore, it could be shown that the sensor has capabilities in performing the marker sensing detection of L-Valine.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article