Your browser doesn't support javascript.
loading
Investigation of different methods in rapid microbial identification directly from positive blood culture bottles by MALDI-TOF MS.
Karadag, Dilan; Ergon, Mahmut Cem.
Afiliação
  • Karadag D; Department of Medical Microbiology, Faculty of Medicine, Dokuz Eylül University, Izmir, Turkey.
  • Ergon MC; IMD Labor Oderland, Frankfurt (Oder), Germany.
Microbiol Spectr ; 12(8): e0063824, 2024 Aug 06.
Article em En | MEDLINE | ID: mdl-38940589
ABSTRACT
Many methods are being tried for rapid and accurate identification of sepsis-causing microorganisms. We analyzed the performance of three different preparation methods [MBT Sepsityper IVD Kit (Bruker Daltonics GmbH, Germany), sodium dodecyl sulfate (SDS) lysis, and differential centrifugation with protein extraction (Centrifugation +PE)] and compared in standard and Sepsityper modules of the Bruker Biotyper MALDI-TOF MS for direct identification of bacteria from 240 positive blood culture bottles of BACTEC FX (Becton Dickinson, USA). By using the standard module, correct identification at species level (score ≥2) was done in 46.7% of the samples with SDS lysis, 44.2% with centrifugation +PE, and 25.4% with the Sepsityper kit. These ratios at the genus level (score range 1.70-1.99) were 34.6%, 31.3%, and 32.5%, respectively. With SDS lysis (195), more bacteria were identified correctly than centrifugation +PE (181) and the Sepsityper kit (139). A statistically significant difference was found between SDS and the Sepsityper kit and Centrifugation +PE and the Sepsityper kit (P < 0.001, both). By using the Sepsityper module, correct identification at species level (score ≥1.8) was determined in 74.2% of the samples with SDS lysis and centrifugation +PE each and 55% with the Sepsityper kit. These ratios at the genus level (score range 1.60-1.79) were 16.3%, 10%, and 19.2%, respectively. SDS lysis (217) had significantly higher identification rates than centrifugation +PE (202) and the Sepsityper kit (178) (P = 0.028 and P < 0.001). A statistically significant difference was also observed between centrifugation +PE and the Sepsityper kit (P < 0.001). Best performance was obtained with SDS lysis among the methods. Although better performance was achieved by using Sepsityper software module, risk of misidentification should not be ignored. IMPORTANCE Sepsis is a life-threatening condition, and rapid and accurate identification of the causative microorganisms from blood cultures is crucial for timely and effective treatment. Although there are many studies on direct identification from blood cultures with MALDI-TOF MS, further standardization is still needed. In our study, we analyzed the performance of three different preparation methods and compared by using two analysis modules of the Bruker Biotyper MALDI-TOF MS for direct identification of bacteria from numerous positive blood culture bottles. The literature reports a limited number of studies that compare different preparation methods for direct blood culture identification, processing a large number of blood samples concurrently and evaluating the same samples as in our study. Moreover, although SDS is used very frequently in medical laboratories, there are few studies on direct identification from blood culture bottles. In our study, the highest correct identification rate was observed with the SDS method.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Bactérias / Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz / Hemocultura Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Bactérias / Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz / Hemocultura Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article