Your browser doesn't support javascript.
loading
Integrating muscle fiber orientation from visible human data into radiotherapy target volumes.
Buti, Gregory; Ajdari, Ali; Chen, Yen-Lin; Bridge, Christopher P; Sharp, Gregory C; Bortfeld, Thomas.
Afiliação
  • Buti G; Massachusetts General Hospital and Harvard Medical School, Department of Radiation Oncology, 100 Blossom St, Boston, MA 02114, United States of America.
  • Ajdari A; Massachusetts General Hospital and Harvard Medical School, Department of Radiation Oncology, 100 Blossom St, Boston, MA 02114, United States of America.
  • Chen YL; Massachusetts General Hospital and Harvard Medical School, Department of Radiation Oncology, 100 Blossom St, Boston, MA 02114, United States of America.
  • Bridge CP; Massachusetts General Hospital and Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, 149 Thirteenth St, Charlestown, MA 02129, United States of America.
  • Sharp GC; Massachusetts General Hospital and Harvard Medical School, Department of Radiation Oncology, 100 Blossom St, Boston, MA 02114, United States of America.
  • Bortfeld T; Massachusetts General Hospital and Harvard Medical School, Department of Radiation Oncology, 100 Blossom St, Boston, MA 02114, United States of America.
Phys Med Biol ; 69(14)2024 Jul 09.
Article em En | MEDLINE | ID: mdl-38942035
ABSTRACT
Objective.A major challenge in treatment of tumors near skeletal muscle is defining the target volume for suspected tumor invasion into the muscle. This study develops a framework that generates radiation target volumes with muscle fiber orientation directly integrated into their definition. The framework is applied to nineteen sacral tumor patients with suspected infiltration into surrounding muscles.Approach.To compensate for the poor soft-tissue contrast of CT images, muscle fiber orientation is derived from cryo-images of two cadavers from the human visible project (VHP). The approach consists of (a) detecting image gradients in the cadaver images representative of muscle fibers, (b) mapping this information onto the patient image, and (c) embedding the muscle fiber orientation into an expansion method to generate patient-specific clinical target volumes (CTV). The validation tested the consistency of image gradient orientation across VHP subjects for the piriformis, gluteus maximus, paraspinal, gluteus medius, and gluteus minimus muscles. The model robustness was analyzed by comparing CTVs generated using different VHP subjects. The difference in shape between the new CTVs and standard CTV was analyzed for clinical impact.Main results.Good agreement was found between the image gradient orientation across VHP subjects, as the voxel-wise median cosine similarity was at least 0.86 (for the gluteus minimus) and up to 0.98 for the piriformis. The volume and surface similarity between the CTVs generating from different VHP subjects was on average at least 0.95 and 5.13 mm for the Dice Similarity Coefficient and the Hausdorff 95% Percentile Index, showing excellent robustness. Finally, compared to the standard CTV with different margins in muscle and non-muscle tissue, the new CTV margins are reduced in muscle tissue depending on the chosen clinical margins.Significance.This study implements a method to integrate muscle fiber orientation into the target volume without the need for additional imaging.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibras Musculares Esqueléticas Limite: Female / Humans / Male Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibras Musculares Esqueléticas Limite: Female / Humans / Male Idioma: En Ano de publicação: 2024 Tipo de documento: Article