Your browser doesn't support javascript.
loading
Autofluorescence lifetime flow cytometry with time-correlated single photon counting.
Samimi, Kayvan; Pasachhe, Ojaswi; Guzman, Emmanuel Contreras; Riendeau, Jeremiah; Gillette, Amani A; Pham, Dan L; Wiech, Kasia J; Moore, Darcie L; Skala, Melissa C.
Afiliação
  • Samimi K; Morgridge Institute for Research, Madison, Wisconsin, USA.
  • Pasachhe O; Morgridge Institute for Research, Madison, Wisconsin, USA.
  • Guzman EC; Morgridge Institute for Research, Madison, Wisconsin, USA.
  • Riendeau J; Morgridge Institute for Research, Madison, Wisconsin, USA.
  • Gillette AA; Morgridge Institute for Research, Madison, Wisconsin, USA.
  • Pham DL; Department of Biomedical Engineering, University of Wisconsin, Madison, Wisconsin, USA.
  • Wiech KJ; Department of Biomedical Engineering, University of Wisconsin, Madison, Wisconsin, USA.
  • Moore DL; Department of Neuroscience, University of Wisconsin, Madison, Wisconsin, USA.
  • Skala MC; Morgridge Institute for Research, Madison, Wisconsin, USA.
Cytometry A ; 105(8): 607-620, 2024 Aug.
Article em En | MEDLINE | ID: mdl-38943226
ABSTRACT
Autofluorescence lifetime imaging microscopy (FLIM) is sensitive to metabolic changes in single cells based on changes in the protein-binding activities of the metabolic co-enzymes NAD(P)H. However, FLIM typically relies on time-correlated single-photon counting (TCSPC) detection electronics on laser-scanning microscopes, which are expensive, low-throughput, and require substantial post-processing time for cell segmentation and analysis. Here, we present a fluorescence lifetime-sensitive flow cytometer that offers the same TCSPC temporal resolution in a flow geometry, with low-cost single-photon excitation sources, a throughput of tens of cells per second, and real-time single-cell analysis. The system uses a 375 nm picosecond-pulsed diode laser operating at 50 MHz, alkali photomultiplier tubes, an FPGA-based time tagger, and can provide real-time phasor-based classification (i.e., gating) of flowing cells. A CMOS camera produces simultaneous brightfield images using far-red illumination. A second PMT provides two-color analysis. Cells are injected into the microfluidic channel using a syringe pump at 2-5 mm/s with nearly 5 ms integration time per cell, resulting in a light dose of 2.65 J/cm2 that is well below damage thresholds (25 J/cm2 at 375 nm). Our results show that cells remain viable after measurement, and the system is sensitive to autofluorescence lifetime changes in Jurkat T cells with metabolic perturbation (sodium cyanide), quiescent versus activated (CD3/CD28/CD2) primary human T cells, and quiescent versus activated primary adult mouse neural stem cells, consistent with prior studies using multiphoton FLIM. This TCSPC-based autofluorescence lifetime flow cytometer provides a valuable label-free method for real-time analysis of single-cell function and metabolism with higher throughput than laser-scanning microscopy systems.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fótons / Citometria de Fluxo Limite: Animals / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fótons / Citometria de Fluxo Limite: Animals / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article