Your browser doesn't support javascript.
loading
Colorimetric enzymatic rapid test for the determination of atropine in baby food using a smartphone.
Domínguez, M; Moraru, D; Lasso, S; Sanz-Vicente, I; de Marcos, S; Galbán, J.
Afiliação
  • Domínguez M; Analytical Chemistry Department, University of Zaragoza, 50009, Saragossa, Spain.
  • Moraru D; Instituto de Nanociencia y Materiales de Aragón (INMA), CSIC-Universidad de Zaragoza, 50009, Saragossa, Spain.
  • Lasso S; Analytical Chemistry Department, University of Zaragoza, 50009, Saragossa, Spain.
  • Sanz-Vicente I; Analytical Chemistry Department, University of Zaragoza, 50009, Saragossa, Spain.
  • de Marcos S; Analytical Chemistry Department, University of Zaragoza, 50009, Saragossa, Spain.
  • Galbán J; Instituto de Nanociencia y Materiales de Aragón (INMA), CSIC-Universidad de Zaragoza, 50009, Saragossa, Spain.
Anal Bioanal Chem ; 2024 Jul 03.
Article em En | MEDLINE | ID: mdl-38960939
ABSTRACT
A method for the enzymatic determination of atropine has been developed, which is based on a sequence of reactions involving (1) the hydrolysis of atropine to give tropine; (2) the enzymatic oxidation of tropine with NAD (catalysed by tropinone reductase); and (3) an indicator reaction, in which the NADH previously formed reduces the dye iodonitrotetrazolium chloride (INT) to a reddish species, the reaction catalysed by diaphorase. The method was first developed in solution (linear response range from 2.4 × 10-6 M to 1.0 × 10-4 M). It was then implemented in cellulose platforms to develop a rapid test where the determination is made by measuring the RGB coordinates of the platforms using a smartphone-based device. The device is based on the integrating sphere concept and contains a light source to avoid external illumination effects. The smartphone is controlled by an app that allows a calibration line to be generated and the atropine concentration to be quantified; moreover, since the app normalizes the CCD response of the smartphone, the results and calibrations obtained with different smartphones are similar and can be shared. Using the G coordinate, the results were shown to have a linear response with the concentration of atropine ranging from 1.2 × 10-5 M to 3.0 × 10-4 M with an RSD of 1.4% (n = 5). The method has been applied to the determination of atropine in baby food and buckwheat samples with good results.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article