Your browser doesn't support javascript.
loading
Rapid Mass Spectrometry-Based Multiattribute Method for Glycation Analysis with Integrated Afucosylation Detection Capability.
Xu, Mengjiao; Liu, Tao; Xu, Jin; Guo, Qingcheng; Ren, Yule; Zhu, Weifan; Zhuang, Huangzhen; Pan, Zhiyuan; Fu, Rongrong; Zhao, Xiang; Wang, Fugui; Mao, Yanni; Song, Lankun; Song, Yang; Ji, Lusha; Qian, Weizhu; Hou, Sheng; Wang, Rui; Li, Jun; Zhang, Dapeng; Guo, Huaizu.
Afiliação
  • Xu M; State Key Laboratory of Macromolecular Drugs and Large-Scale Manufacturing, School of Pharmaceutical Sciences, Liaocheng University, Liaocheng 252059, China.
  • Liu T; NMPA Key Laboratory for Quality Control of Therapeutic Monoclonal Antibodies, Shanghai 201203, China.
  • Xu J; State Key Laboratory of Macromolecular Drugs and Large-Scale Manufacturing, School of Pharmaceutical Sciences, Liaocheng University, Liaocheng 252059, China.
  • Guo Q; NMPA Key Laboratory for Quality Control of Therapeutic Monoclonal Antibodies, Shanghai 201203, China.
  • Ren Y; State Key Laboratory of Macromolecular Drugs and Large-Scale Manufacturing, School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou 325035, China.
  • Zhu W; Department of Oncology, Huashan Hospital, Fudan University, Shanghai 200040, China.
  • Zhuang H; State Key Laboratory of Macromolecular Drugs and Large-Scale Manufacturing, School of Pharmaceutical Sciences, Liaocheng University, Liaocheng 252059, China.
  • Pan Z; NMPA Key Laboratory for Quality Control of Therapeutic Monoclonal Antibodies, Shanghai 201203, China.
  • Fu R; State Key Laboratory of Macromolecular Drugs and Large-Scale Manufacturing, School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou 325035, China.
  • Zhao X; State Key Laboratory of Macromolecular Drugs and Large-Scale Manufacturing, School of Pharmaceutical Sciences, Liaocheng University, Liaocheng 252059, China.
  • Wang F; NMPA Key Laboratory for Quality Control of Therapeutic Monoclonal Antibodies, Shanghai 201203, China.
  • Mao Y; State Key Laboratory of Macromolecular Drugs and Large-Scale Manufacturing, School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou 325035, China.
  • Song L; Taizhou Mabtech Pharmaceuticals Co., Ltd., Taizhou 225316, China.
  • Song Y; State Key Laboratory of Macromolecular Drugs and Large-Scale Manufacturing, School of Pharmaceutical Sciences, Liaocheng University, Liaocheng 252059, China.
  • Ji L; NMPA Key Laboratory for Quality Control of Therapeutic Monoclonal Antibodies, Shanghai 201203, China.
  • Qian W; State Key Laboratory of Macromolecular Drugs and Large-Scale Manufacturing, School of Pharmaceutical Sciences, Liaocheng University, Liaocheng 252059, China.
  • Hou S; NMPA Key Laboratory for Quality Control of Therapeutic Monoclonal Antibodies, Shanghai 201203, China.
  • Wang R; State Key Laboratory of Macromolecular Drugs and Large-Scale Manufacturing, School of Pharmaceutical Sciences, Liaocheng University, Liaocheng 252059, China.
  • Li J; NMPA Key Laboratory for Quality Control of Therapeutic Monoclonal Antibodies, Shanghai 201203, China.
  • Zhang D; State Key Laboratory of Macromolecular Drugs and Large-Scale Manufacturing, School of Pharmaceutical Sciences, Liaocheng University, Liaocheng 252059, China.
  • Guo H; NMPA Key Laboratory for Quality Control of Therapeutic Monoclonal Antibodies, Shanghai 201203, China.
J Am Soc Mass Spectrom ; 35(8): 1669-1679, 2024 Aug 07.
Article em En | MEDLINE | ID: mdl-38970800
ABSTRACT
The multiattribute method (MAM) has emerged as a powerful tool for simultaneously screening multiple product quality attributes of therapeutic antibodies. One such potential critical quality attribute (CQA) is glycation, a common modification that can impact the heterogeneity, functional activity, and immunogenicity of therapeutic antibodies. However, current methods for monitoring glycation levels in MAM are rare and not sufficiently rapid and accurate. In this study, an improved mass spectrometry (MS)-based MAM was developed to simultaneously monitor glycation and other quality attributes including afucosylation. The method was evaluated using two therapeutic antibodies with different glycosylation site numbers. Treatment with IdeS, Endo F2, and dithiothreitol generated three distinct subunits, and the glycation results obtained were similar to those treated with PNGase F, which is routinely used to release glycans; the sample processing time was greatly reduced while providing additional quality attribute information. The MS-based MAM was also employed to assess the glycation progression following forced glycation in various buffer solutions. A significant increase in oxidation was observed when forced glycation was conducted in an ammonium bicarbonate buffer solution, and a total of 23 potential glycation sites and 4 significantly oxidized sites were identified. Notably, we found that ammonium bicarbonate was found to specifically stimulate oxidation, while glycation had a synergistic effect on oxidation. These findings establish this study as a novel methodology for achieving a technologically advanced platform and concept that enhances the efficacy of product development and quality control, characterized by its broad-spectrum, rapid, and accurate nature.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas Idioma: En Ano de publicação: 2024 Tipo de documento: Article