Your browser doesn't support javascript.
loading
A Novel Multiplex LAMP Assay for the Detection of Respiratory Human Adenoviruses.
Koryukov, Maksim A; Oscorbin, Igor P; Novikova, Lidiya M; Gordukova, Maria A; Turina, Irina E; Galeeva, Elena V; Kudlay, Dmitry A; Filipenko, Maxim L.
Afiliação
  • Koryukov MA; The Institute of Chemical Biology and Fundamental Medicine, Siberian Branch of the Russian Academy of Sciences, 8 Lavrentiev Avenue, Novosibirsk 630090, Russia.
  • Oscorbin IP; Department of Natural Sciences, Novosibirsk State University, Novosibirsk 630090, Russia.
  • Novikova LM; The Institute of Chemical Biology and Fundamental Medicine, Siberian Branch of the Russian Academy of Sciences, 8 Lavrentiev Avenue, Novosibirsk 630090, Russia.
  • Gordukova MA; The Institute of Chemical Biology and Fundamental Medicine, Siberian Branch of the Russian Academy of Sciences, 8 Lavrentiev Avenue, Novosibirsk 630090, Russia.
  • Turina IE; G. Speransky Children's Hospital No. 9, 29 Shmitovsky Prospect, Moscow 123317, Russia.
  • Galeeva EV; Department of Natural Sciences, I.M. Sechenov First Moscow State Medical University, Pogodinskaya St. 1, Moscow 119991, Russia.
  • Kudlay DA; G. Speransky Children's Hospital No. 9, 29 Shmitovsky Prospect, Moscow 123317, Russia.
  • Filipenko ML; Department of Natural Sciences, I.M. Sechenov First Moscow State Medical University, Pogodinskaya St. 1, Moscow 119991, Russia.
Int J Mol Sci ; 25(13)2024 Jun 29.
Article em En | MEDLINE | ID: mdl-39000322
ABSTRACT
Human adenoviruses (HAdVs) are common pathogens that are associated with a variety of diseases, including respiratory tract infections (RTIs). Without reliable, fast, and cost-effective detection methods for HAdVs, patients may be misdiagnosed and inappropriately treated. To address this problem, we have developed a multiplex loop-mediated isothermal amplification (LAMP) assay for the detection of the species Human adenovirus B (HAdV-B), Human adenovirus C (HAdV-C) and Human adenovirus E (HAdV-E) that cause RTIs. This multiplexing approach is based on the melting curve analysis of the amplicons with a specific melting temperature for each HAdV species. Without the need for typing of HAdVs, the LAMP results can be visually detected using colorimetric analysis. The assay reliably detects at least 375 copies of HAdV-B and -C and 750 copies of HAdV-E DNA per reaction in less than 35 min at 60 °C. The designed primers have no in silico cross-reactivity with other human respiratory pathogens. Validation on 331 nasal swab samples taken from patients with RTIs showed a 90-94% agreement rate with our in-house multiplex quantitative polymerase chain reaction (qPCR) method. Concordance between the quantitative and visual LAMP was 99%. The novel multiplexed LAMP could be an alternative to PCR for diagnostic purposes, saving personnel and equipment time, or could be used for point-of-care testing.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Infecções Respiratórias / Adenovírus Humanos / Técnicas de Amplificação de Ácido Nucleico / Técnicas de Diagnóstico Molecular Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Infecções Respiratórias / Adenovírus Humanos / Técnicas de Amplificação de Ácido Nucleico / Técnicas de Diagnóstico Molecular Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article