Your browser doesn't support javascript.
loading
Incorporating boron distribution variations in microdosimetric kinetic model-based relative biological effectiveness calculations for boron neutron capture therapy.
Li, Mingzhu; Geng, Changran; Han, Yang; Guan, Fada; Liu, Yuanhao; Shu, Diyun; Tang, Xiaobin.
Afiliação
  • Li M; Department of Nuclear Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing, 211106, China.
  • Geng C; Joint International Research Laboratory on Advanced Particle Therapy, Nanjing University of Aeronautics and Astronautics, Nanjing, 211100, China.
  • Han Y; Department of Nuclear Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing, 211106, China.
  • Guan F; Joint International Research Laboratory on Advanced Particle Therapy, Nanjing University of Aeronautics and Astronautics, Nanjing, 211100, China.
  • Liu Y; Department of Nuclear Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing, 211106, China.
  • Shu D; Joint International Research Laboratory on Advanced Particle Therapy, Nanjing University of Aeronautics and Astronautics, Nanjing, 211100, China.
  • Tang X; Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut, 06530, United States.
Article em En | MEDLINE | ID: mdl-39010755
ABSTRACT
This study introduces the MKM_B model, an approach derived from the MKM model, designed to evaluate the biological effectiveness of Boron Neutron Capture Therapy (BNCT) in the face of challenges from varying microscopic boron distributions. The model introduces a boron compensation factor, allowing for the assessment of compound Biological Effectiveness (CBE) values for different boron distributions. Utilizing the TOPAS simulation platform, the lineal energy spectrum of particles in BNCT was simulated, and the sensitivity of the MKM_B model to parameter variations and the influence of cell size on the model were thoroughly investigated. The CBE values for 10B-boronphenylalanine (BPA) and 10B-sodium (BSH) were determined to be 3.70 and 1.75, respectively. These calculations were based on using the nucleus radius of 2.5 µm and the cell radius of 5 µm while considering a 50% surviving fraction. It was observed that as cell size decreased, the CBE values for both BPA and BSH increased. Additionally, the model parameter rd was identified as having the most significant impact on CBE, with other parameters showing moderate effects. The development of the MKM_B model enables the accurate prediction of CBE under different boron distributions in BNCT. This model offers a promising approach to optimize treatment planning by providing increased accuracy in biological effectiveness.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article