Your browser doesn't support javascript.
loading
Sutureless Valves, a "Wireless" Option for Patients With Aortic Valve Disease: JACC State-of-the-Art Review.
Spadaccio, Cristiano; Nenna, Antonio; Pisani, Angelo; Laskawski, Grzegorz; Nappi, Francesco; Moon, Marc R; Biancari, Fausto; Jassar, Arminder S; Greason, Kevin L; Shrestha, Malakh L; Bonaros, Nikolaos; Rose, David.
Afiliação
  • Spadaccio C; Cardiothoracic Surgery, Lancashire Cardiac Centre/Blackpool Teaching Hospital, Blackpool, United Kingdom; Cardiovascular Surgery, Mayo Clinic, Rochester, Minnesota, USA. Electronic address: cristianospadaccio@gmail.com.
  • Nenna A; Cardiovascular Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Rome, Italy.
  • Pisani A; Cardiac Surgery, Hôpital Bichat - Claude-Bernard, Paris, France.
  • Laskawski G; Cardiothoracic Surgery, Lancashire Cardiac Centre/Blackpool Teaching Hospital, Blackpool, United Kingdom.
  • Nappi F; Cardiac Surgery, Centre Cardiologique du Nord de Saint-Denis, Paris, France.
  • Moon MR; Cardiothoracic Surgery, Baylor College of Medicine/Texas Heart Institute, Houston, Texas, USA.
  • Biancari F; Heart and Lung Center, Helsinki University Hospital/University of Helsinki, Helsinki, Finland.
  • Jassar AS; Cardiac Surgery, Massachusetts General Hospital (MGH), Boston, Massachusetts, USA.
  • Greason KL; Cardiovascular Surgery, Mayo Clinic, Rochester, Minnesota, USA.
  • Shrestha ML; Cardiovascular Surgery, Mayo Clinic, Rochester, Minnesota, USA; Cardiothoracic Surgery, Hannover Medical School, Hannover, Germany.
  • Bonaros N; Cardiac Surgery, Medical University of Innsbruck, Innsbruck, Austria.
  • Rose D; Cardiothoracic Surgery, Lancashire Cardiac Centre/Blackpool Teaching Hospital, Blackpool, United Kingdom.
J Am Coll Cardiol ; 84(4): 382-407, 2024 Jul 23.
Article em En | MEDLINE | ID: mdl-39019533
ABSTRACT
Transcatheter technologies triggered the recent revision of the guidelines that progressively widened the indications for the treatment of aortic stenosis. On the surgical realm, a technology avoiding the need for sutures to anchor the prosthesis to the aortic annulus has been developed with the aim to reduce the duration of cardiopulmonary bypass and simplify the process of valve implantation. In addition to a transcatheter aortic valve replacement (TAVR)-like stent that exerts a radial force, these so-called "rapid deployment valves" or "sutureless valves" for aortic valve replacement also have cuffs to improve sealing and reduce the risk of paravalvular leak. Despite promising, the actual advantage of sutureless valves over traditional surgical procedures (surgical aortic valve replacement) or TAVR is still debated. This review summarizes the current comparative evidence reporting outcomes of "sutureless valves" for aortic valve replacement to TAVR and surgical aortic valve replacement in the treatment of aortic valve stenosis.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Próteses Valvulares Cardíacas / Substituição da Valva Aórtica Transcateter Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Próteses Valvulares Cardíacas / Substituição da Valva Aórtica Transcateter Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article